Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring. To overcome these limitations, we developed a nanoencapsulated optical fiber (OF)-based PEC microelectrode. The microelectrode features TiO<sub>2</sub>/CdS nanocrystals and bis (2,2'-bipyridine) (10-methylphenanthroline [3,2-<i>a</i>:2'3'-<i>c</i>] pyridine ruthenium(II) dichloride ([Ru(bpy)<sub>2</sub>dppz]<sup>2+</sup>) @dsDNA/Au@epigallocatechin gallate nanoparticle (EGCG NP) layers. And its application for the detection of N-terminal pro-brain natriuretic peptide (NT-proBNP) as a biomarker of cardiovascular diseases was explored. An extensive linear range of 1-5000 pg mL<sup>-1</sup> combined with a low detection limit of 0.36 pg mL<sup>-1</sup> was achieved. This range covers not only the recommended threshold for excluding cardiovascular diseases in the clinical diagnosis of individuals across all age groups but also the prognostic target value. The sensor exhibited excellent selectivity and stability and notable labeling recovery capability in serum tests. Critically, the sensor successfully discriminated the alterations in NT-proBNP secretion levels within human smooth muscle cells, comparing pre- and poststimulation by platelet-derived growth factor-BB. Even more significantly, the skin puncture experiment conducted in mice demonstrated the remarkable implantability and biological compatibility of the OF-PEC microelectrode. This addresses critical challenges commonly faced by microelectrodes when used as implanted devices, such as minimizing invasive trauma, mitigating inflammation, and preventing biofouling, thereby firmly establishing their suitability for the development of advanced implantable sensing devices. Therefore, the present OF microelectrode PEC biosensor is not only cost-effective, easy to operate, and miniaturized but also holds significant potential for enabling more precise, more minimally invasive, and continuous monitoring of biological markers without causing inflammation. This capability is crucial for early disease detection, tracking disease progression, and facilitating personalized treatment strategies, which expands the practical application of PEC sensors.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-01-27
DOI
https://doi.org/10.1021/acs.analchem.4c04757
Citations
19
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
11.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance

Yuancheng Liu, Wuming Wu, Jingjing Zhou, ErKang Bian et al.
19 citations
Analytical Chemistry
Conducting polymers and applications
11.53
article

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance

Yuancheng Liu, Wuming Wu, Jingjing Zhou, ErKang Bian, Shengqing Li, Chunyan Deng, Huijuan Guo, Yicheng Yang, HuiYu Zou, Zhizhong Jiang
article en
19 citations

Abstract

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring. To overcome these limitations, we developed a nanoencapsulated optical fiber (OF)-based PEC microelectrode. The microelectrode features TiO<sub>2</sub>/CdS nanocrystals and bis (2,2'-bipyridine) (10-methylphenanthroline [3,2-<i>a</i>:2'3'-<i>c</i>] pyridine ruthenium(II) dichloride ([Ru(bpy)<sub>2</sub>dppz]<sup>2+</sup>) @dsDNA/Au@epigallocatechin gallate nanoparticle (EGCG NP) layers. And its application for the detection of N-terminal pro-brain natriuretic peptide (NT-proBNP) as a biomarker of cardiovascular diseases was explored. An extensive linear range of 1-5000 pg mL<sup>-1</sup> combined with a low detection limit of 0.36 pg mL<sup>-1</sup> was achieved. This range covers not only the recommended threshold for excluding cardiovascular diseases in the clinical diagnosis of individuals across all age groups but also the prognostic target value. The sensor exhibited excellent selectivity and stability and notable labeling recovery capability in serum tests. Critically, the sensor successfully discriminated the alterations in NT-proBNP secretion levels within human smooth muscle cells, comparing pre- and poststimulation by platelet-derived growth factor-BB. Even more significantly, the skin puncture experiment conducted in mice demonstrated the remarkable implantability and biological compatibility of the OF-PEC microelectrode. This addresses critical challenges commonly faced by microelectrodes when used as implanted devices, such as minimizing invasive trauma, mitigating inflammation, and preventing biofouling, thereby firmly establishing their suitability for the development of advanced implantable sensing devices. Therefore, the present OF microelectrode PEC biosensor is not only cost-effective, easy to operate, and miniaturized but also holds significant potential for enabling more precise, more minimally invasive, and continuous monitoring of biological markers without causing inflammation. This capability is crucial for early disease detection, tracking disease progression, and facilitating personalized treatment strategies, which expands the practical application of PEC sensors.

Analytical ChemistryVol. 97(5)
Central South University (CN), Capital University (US), Capital Medical University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Beijing Anzhen Hospital (CN), Interface (United Kingdom) (GB), Xiangya Hospital Central South University (CN), Fu Wai Hospital (CN), Hunan Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 1%
Conducting polymers and applications
11.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.