A Droplet Microfluidic Sensor for Point-of-Care Measurement of Plasma/Serum Total Free Thiol Concentrations

Total free thiols are an important marker of the whole-body redox state, which has been shown to be associated with clinical outcome in health and disease. Recent investigations have suggested that increased insight may be gained by monitoring alterations of redox state in response to exercise and hypoxia and to monitor redox trajectories in disease settings. However, conducting such studies is challenging due to the requirement for repeated venous blood sampling and intensive lab work. Droplet microfluidic sensors offer an alternative platform for developing a point-of-care testing approach using small sample volumes and automated systems to complement or ultimately replace laboratory testing. Here we developed a small, portable droplet microfluidic sensor that can measure total free thiol concentrations in 20 μL human plasma (or serum) samples, providing a reading in less than 10 min. This system features a novel method to enhance the mixing of reagent and analyte in droplets containing viscous biological fluids. The results in a range of real-world human plasma samples showed equivalence with current standard laboratory assays while reducing sample volume requirements 9-fold and fully automating the process. Micro hematocrit capillaries allowed testing of capillary blood samples collected by fingerprick lancing. The system was used to monitor total free thiols using fingerprick samples in healthy volunteers and revealed significant changes in total free thiols in response to food intake and exercise. This device has the potential to improve our ability to conduct physiological studies of total free thiol level changes and improve our understanding of redox physiology, which may ultimately be applied in redox medicine to improve patient care.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-01-27
DOI
https://doi.org/10.1021/acs.analchem.4c04163
Citations
2
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Droplet Microfluidic Sensor for Point-of-Care Measurement of Plasma/Serum Total Free Thiol Concentrations

Martin Feelisch, Adrian M. Nightingale, Xize Niu, Liam Carter
2 citations
Analytical Chemistry
Innovative Microfluidic and Catalytic Techniques Innovation
1.35
article

A Droplet Microfluidic Sensor for Point-of-Care Measurement of Plasma/Serum Total Free Thiol Concentrations

Martin Feelisch, Adrian M. Nightingale, Xize Niu, Liam Carter
article en
2 citations

Abstract

Total free thiols are an important marker of the whole-body redox state, which has been shown to be associated with clinical outcome in health and disease. Recent investigations have suggested that increased insight may be gained by monitoring alterations of redox state in response to exercise and hypoxia and to monitor redox trajectories in disease settings. However, conducting such studies is challenging due to the requirement for repeated venous blood sampling and intensive lab work. Droplet microfluidic sensors offer an alternative platform for developing a point-of-care testing approach using small sample volumes and automated systems to complement or ultimately replace laboratory testing. Here we developed a small, portable droplet microfluidic sensor that can measure total free thiol concentrations in 20 μL human plasma (or serum) samples, providing a reading in less than 10 min. This system features a novel method to enhance the mixing of reagent and analyte in droplets containing viscous biological fluids. The results in a range of real-world human plasma samples showed equivalence with current standard laboratory assays while reducing sample volume requirements 9-fold and fully automating the process. Micro hematocrit capillaries allowed testing of capillary blood samples collected by fingerprick lancing. The system was used to monitor total free thiols using fingerprick samples in healthy volunteers and revealed significant changes in total free thiols in response to food intake and exercise. This device has the potential to improve our ability to conduct physiological studies of total free thiol level changes and improve our understanding of redox physiology, which may ultimately be applied in redox medicine to improve patient care.

Analytical ChemistryVol. 97(5)
University Hospital Southampton NHS Foundation Trust (GB), Scientific Research Institute of Experimental and Clinical Medicine (RU), Physical Sciences (United States) (US), NIHR Southampton Biomedical Research Centre (GB), University of Southampton (GB)
UK Research and Innovation, British Skin Foundation, Sight Research UK, University of Southampton, Engineering and Physical Sciences Research Council, Natural Environment Research Council
Openalex Percentile: Top 23%
Innovative Microfluidic and Catalytic Techniques Innovation
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.