Leadless Pacemaker Implantation Following Lead Extraction in a Patient With Recent Percutaneous Tricuspid Valve Repair

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system. A leadless pacemaker was subsequently implanted without complications, despite the recent tricuspid valve repair. This case highlights the efficacy and safety of leadless pacemakers in complex clinical scenarios, especially when traditional transvenous systems are no longer viable due to infections or other complications. The report underscores the importance of personalized management strategies for cardiac device infections, illustrating that leadless pacemakers offer a feasible and safe alternative even in patients with previous valvular interventions.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2025-01-27
DOI
https://doi.org/10.1111/pace.15150
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Leadless Pacemaker Implantation Following Lead Extraction in a Patient With Recent Percutaneous Tricuspid Valve Repair

Giulio Zucchelli, Lorenzo Pistelli, Marco Torre, Andrea Di Cori et al.
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Leadless Pacemaker Implantation Following Lead Extraction in a Patient With Recent Percutaneous Tricuspid Valve Repair

Giulio Zucchelli, Lorenzo Pistelli, Marco Torre, Andrea Di Cori, Luca Segreti, M Parollo
article en

Abstract

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system. A leadless pacemaker was subsequently implanted without complications, despite the recent tricuspid valve repair. This case highlights the efficacy and safety of leadless pacemakers in complex clinical scenarios, especially when traditional transvenous systems are no longer viable due to infections or other complications. The report underscores the importance of personalized management strategies for cardiac device infections, illustrating that leadless pacemakers offer a feasible and safe alternative even in patients with previous valvular interventions.

Pacing and Clinical ElectrophysiologyVol. 48(3)
Azienda Ospedaliera Universitaria Pisana (IT)
Good health and well-being
Openalex Percentile: Top 98%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Leadless Pacemaker Implantation Following Lead Extraction in a Patient With Recent Percutaneous Tricuspid Valve Repair — Giulio Zucchelli, Lorenzo Pistelli, et al. · Pacing and Clinical Electrophysiology (2025) | TGRS Research Map | TGRS