A niobium nitride superconducting hot electron bolometer direct terahertz detector working at 9 K

Increasing the bath temperature of the hot electron bolometer (HEB) while ensuring sensitivity could expand the application field and reduce the system complexity and cost. This study proposed and prepared a suspended NbN/Nb5N6 HEB with doubled bath temperature and undegraded sensitivity compared to NbN HEB. Under the bath temperature of 9 K, the optical noise equivalent power of the system was still of the order of pW/Hz1/2. Moreover, the influence of thermal relaxation on the device sensitivity was simulated. The results would provide a pathway for improving the bath temperature and detector sensitivity through fine adjustments of the thermal boundaries.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2025-01-27
DOI
https://doi.org/10.1063/5.0231315
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A niobium nitride superconducting hot electron bolometer direct terahertz detector working at 9 K

Jian Chen, Xiaoqing Jia, Xuecou Tu, Hongkai Shi et al.
Applied Physics Letters
Superconducting and THz Device Technology
article

A niobium nitride superconducting hot electron bolometer direct terahertz detector working at 9 K

Jian Chen, Xiaoqing Jia, Xuecou Tu, Hongkai Shi, Runfeng Su, Peiheng Wu, Tao Xu, Kebin Fan, Lin Kang, Han Bao, Yijun Zhe, Jianfeng Li
article en

Abstract

Increasing the bath temperature of the hot electron bolometer (HEB) while ensuring sensitivity could expand the application field and reduce the system complexity and cost. This study proposed and prepared a suspended NbN/Nb5N6 HEB with doubled bath temperature and undegraded sensitivity compared to NbN HEB. Under the bath temperature of 9 K, the optical noise equivalent power of the system was still of the order of pW/Hz1/2. Moreover, the influence of thermal relaxation on the device sensitivity was simulated. The results would provide a pathway for improving the bath temperature and detector sensitivity through fine adjustments of the thermal boundaries.

Applied Physics LettersVol. 126(4)
University of Science and Technology of China (CN), Hefei University (CN), CAS Key Laboratory of Urban Pollutant Conversion (CN), Purple Mountain Laboratories (CN), Nanjing University (CN)
National Natural Science Foundation of China, Priority Academic Program Development of Jiangsu Higher Education Institutions, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 99%
Superconducting and THz Device Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A niobium nitride superconducting hot electron bolometer direct terahertz detector working at 9 K — Jian Chen, Xiaoqing Jia, et al. · Applied Physics Letters (2025) | TGRS Research Map | TGRS