Magnetic field tunable spectral response of kinetic inductance detectors

We tune the onset of optical response in aluminum kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in the spectral response is due to the decrease in the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift, and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysterically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2025-01-27
DOI
https://doi.org/10.1063/5.0231368
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic field tunable spectral response of kinetic inductance detectors

A. Gómez, A. Monfardini, U. Chowdhury, J. Goupy et al.
Applied Physics Letters
Superconducting and THz Device Technology
article

Magnetic field tunable spectral response of kinetic inductance detectors

A. Gómez, A. Monfardini, U. Chowdhury, J. Goupy, F. Lévy-Bertrand, M. Calvo
article en

Abstract

We tune the onset of optical response in aluminum kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in the spectral response is due to the decrease in the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift, and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysterically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.

Applied Physics LettersVol. 126(4)
Institut polytechnique de Grenoble (FR), Centre National de la Recherche Scientifique (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), CEA Grenoble (FR), Direction de la Recherche Fondamentale (FR), Centro de Astrobiología (ES), Institut Néel (FR), Deleted Institution, Université Grenoble Alpes (FR)
Agence Nationale de la Recherche, Ministerio de Ciencia e Innovación, European Research Council
Openalex Percentile: Top 99%
Superconducting and THz Device Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Magnetic field tunable spectral response of kinetic inductance detectors — A. Gómez, A. Monfardini, et al. · Applied Physics Letters (2025) | TGRS Research Map | TGRS