Accelerated and precise skin cancer detection through an enhanced machine learning pipeline for improved diagnostic accuracy

Unrepaired DNA damage in skin cells causes mutations leading to skin cancer, a highly aggressive malignancy. This study proposes a machine learning (ML)-based framework for accurate and automated skin cancer detection, integrating EfficientNetV2L for advanced feature extraction and LightGBM (LGBM) for gradient boosting. The ensemble model effectively classifies benign and malignant skin lesions, leveraging EfficientNetV2L's feature extraction capabilities and LGBM's computational efficiency. A dataset comprising 3,297 images of benign and malignant skin cancer classes was used for training. Data augmentation techniques were applied to enhance dataset reliability. The proposed training pipeline, optimized for modularity and performance, demonstrated significant improvements in accuracy and computational efficiency over state-of-the-art methods. The model achieved a training accuracy of 99.57% and a validation accuracy of 99.93%. Using 5-fold cross-validation, it recorded a test accuracy of 99.90% in the fifth fold. For benign cases, the model achieved a precision of 0.99, recall of 0.98, and F1-score of 0.98. Similarly, malignant cases achieved a precision of 0.98, recall of 0.98, and F1-score of 0.98. The ROC-AUC scores for both classes were 0.98, further validating the system's reliability. These results highlight the robustness and effectiveness of the EfficientNetV2L-LGBM framework in skin cancer classification, offering a reliable and scalable solution for early detection. This approach demonstrates significant potential in advancing diagnostic systems for improved patient outcomes. • EfficientNetV2L-LGBM hybrid model for accurate and automated skin cancer detection. • 99.57% training accuracy, 99.93% validation accuracy, 99.90% test accuracy achieved. • Reduced computational requirements, ensuring suitability for medical applications. • State-of-the-art method in reliability and precision for skin cancer classification. • Scalable solution for improving the efficiency of future medical diagnostic system.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-01-27
DOI
https://doi.org/10.1016/j.rineng.2025.104168
Citations
35
Primary Topic
Cutaneous Melanoma Detection and Management
Type
article
Field-Weighted Citation Impact
36.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accelerated and precise skin cancer detection through an enhanced machine learning pipeline for improved diagnostic accuracy

Veerpratap Meena, Preeti Meena, Abhishek Appaji, Jitendra Bahadur et al.
35 citations
Results in Engineering
Cutaneous Melanoma Detection and Management
36.59
article

Accelerated and precise skin cancer detection through an enhanced machine learning pipeline for improved diagnostic accuracy

Veerpratap Meena, Preeti Meena, Abhishek Appaji, Jitendra Bahadur, S. M. Nuruzzaman Nobel, S M Masfequier Rahman Swapno
article en
35 citations

Abstract

Unrepaired DNA damage in skin cells causes mutations leading to skin cancer, a highly aggressive malignancy. This study proposes a machine learning (ML)-based framework for accurate and automated skin cancer detection, integrating EfficientNetV2L for advanced feature extraction and LightGBM (LGBM) for gradient boosting. The ensemble model effectively classifies benign and malignant skin lesions, leveraging EfficientNetV2L's feature extraction capabilities and LGBM's computational efficiency. A dataset comprising 3,297 images of benign and malignant skin cancer classes was used for training. Data augmentation techniques were applied to enhance dataset reliability. The proposed training pipeline, optimized for modularity and performance, demonstrated significant improvements in accuracy and computational efficiency over state-of-the-art methods. The model achieved a training accuracy of 99.57% and a validation accuracy of 99.93%. Using 5-fold cross-validation, it recorded a test accuracy of 99.90% in the fifth fold. For benign cases, the model achieved a precision of 0.99, recall of 0.98, and F1-score of 0.98. Similarly, malignant cases achieved a precision of 0.98, recall of 0.98, and F1-score of 0.98. The ROC-AUC scores for both classes were 0.98, further validating the system's reliability. These results highlight the robustness and effectiveness of the EfficientNetV2L-LGBM framework in skin cancer classification, offering a reliable and scalable solution for early detection. This approach demonstrates significant potential in advancing diagnostic systems for improved patient outcomes. • EfficientNetV2L-LGBM hybrid model for accurate and automated skin cancer detection. • 99.57% training accuracy, 99.93% validation accuracy, 99.90% test accuracy achieved. • Reduced computational requirements, ensuring suitability for medical applications. • State-of-the-art method in reliability and precision for skin cancer classification. • Scalable solution for improving the efficiency of future medical diagnostic system.

Results in EngineeringVol. 25
Bangladesh University of Engineering and Technology (BD), National Institute of Technology Jamshedpur (IN), Indian Institute of Science Education and Research, Bhopal (IN), Maastricht University (NL), Bangalore Medical Center (IN), Bangladesh University of Business and Technology (BD), Amrita Vishwa Vidyapeetham (IN), Bangalore Medical College and Research Institute (IN)
Good health and well-being
Openalex Percentile: Top 0%
Cutaneous Melanoma Detection and Management
36.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.