Retinal reconstruction from peripheral biometry

This study presents a method for retinal reconstruction using peripheral biometry. The incident beam is presumed to be directed toward the center of curvature of the anterior cornea, reaching the retina with minimal deviation. A significant advancement is demonstrated by extending previous approaches to three dimensions and effectively capturing the complexity of astigmatic corneal surfaces. The method was evaluated in Zemax using Navarro's eye model featuring a retina of 12 mm radius, across various levels of accommodation ranging from 0 to 8 D, and a visual field angle between 25 and 25°. The method's reliability diminishes for field angles ≥ 35°. Validation was carried out using 500 synthetically generated eyes, and the method's performance was also assessed with an ellipsoidal retina. The findings revealed that spherical equivalent differences were consistently under 0.25 D at 25° for both types of retinas. Overall, these results demonstrate the method's effectiveness, offering a promising new tool for retinal reconstruction.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-01-27
DOI
https://doi.org/10.1364/boe.549290
Citations
2
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retinal reconstruction from peripheral biometry

Iñaki Blanco-Martínez, David A. Atchison, Fuensanta A. Vera‐Díaz, J. Rozema
2 citations
Biomedical Optics Express
Retinal and Macular Surgery
2.72
article

Retinal reconstruction from peripheral biometry

Iñaki Blanco-Martínez, David A. Atchison, Fuensanta A. Vera‐Díaz, J. Rozema
article en
2 citations

Abstract

This study presents a method for retinal reconstruction using peripheral biometry. The incident beam is presumed to be directed toward the center of curvature of the anterior cornea, reaching the retina with minimal deviation. A significant advancement is demonstrated by extending previous approaches to three dimensions and effectively capturing the complexity of astigmatic corneal surfaces. The method was evaluated in Zemax using Navarro's eye model featuring a retina of 12 mm radius, across various levels of accommodation ranging from 0 to 8 D, and a visual field angle between 25 and 25°. The method's reliability diminishes for field angles ≥ 35°. Validation was carried out using 500 synthetically generated eyes, and the method's performance was also assessed with an ellipsoidal retina. The findings revealed that spherical equivalent differences were consistently under 0.25 D at 25° for both types of retinas. Overall, these results demonstrate the method's effectiveness, offering a promising new tool for retinal reconstruction.

Biomedical Optics ExpressVol. 16(4)
University of Antwerp (BE), Queensland University of Technology (AU), New England College of Optometry (US), Antwerp University Hospital (BE), University of Minho (PT)
Openalex Percentile: Top 13%
Retinal and Macular Surgery
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Retinal reconstruction from peripheral biometry — Iñaki Blanco-Martínez, David A. Atchison, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS