Sensitive hydrogen detection using off-axis integrated cavity output spectroscopy at 2.1 <i>μ</i>m

Reliable hydrogen (H2) detection is essential for advancing hydrogen energy applications. In this study, we report a sensitive H2 detection method using off-axis integrated cavity output spectroscopy. A distributed-feedback laser with fiber output was used to target the H2 absorption transition near 2122 nm. The optical cavity was constructed using two spherical mirrors, each with a reflectivity of 99.985%, providing an effective absorption path length of 2500 m. The Galatry line shape function was selected to accurately fit the narrow absorption feature of H2. Furthermore, we achieved a 1.74-fold improvement in the signal-to-noise ratio by applying radio frequency white noise perturbations. The system's performance was demonstrated by measuring H2 mixtures across a broad concentration range from 1040 ppm to 20.24%. Finally, the Allan–Werle deviation analysis revealed a detection limit of 53 ppm H2 at an average time of 400 s.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2025-01-27
DOI
https://doi.org/10.1063/5.0250199
Citations
8
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
6.05

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive hydrogen detection using off-axis integrated cavity output spectroscopy at 2.1 μm

Wei Ren, Zhen Wang, Mai Hu, Kun Duan et al.
8 citations
Applied Physics Letters
Spectroscopy and Laser Applications
6.05
article

Sensitive hydrogen detection using off-axis integrated cavity output spectroscopy at 2.1 μm

Wei Ren, Zhen Wang, Mai Hu, Kun Duan, Gang Lyu
article en
8 citations

Abstract

Reliable hydrogen (H2) detection is essential for advancing hydrogen energy applications. In this study, we report a sensitive H2 detection method using off-axis integrated cavity output spectroscopy. A distributed-feedback laser with fiber output was used to target the H2 absorption transition near 2122 nm. The optical cavity was constructed using two spherical mirrors, each with a reflectivity of 99.985%, providing an effective absorption path length of 2500 m. The Galatry line shape function was selected to accurately fit the narrow absorption feature of H2. Furthermore, we achieved a 1.74-fold improvement in the signal-to-noise ratio by applying radio frequency white noise perturbations. The system's performance was demonstrated by measuring H2 mixtures across a broad concentration range from 1040 ppm to 20.24%. Finally, the Allan–Werle deviation analysis revealed a detection limit of 53 ppm H2 at an average time of 400 s.

Applied Physics LettersVol. 126(4)
Chinese University of Hong Kong (HK)
National Natural Science Foundation of China, University Grants Committee
Openalex Percentile: Top 4%
Spectroscopy and Laser Applications
6.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.