The influence of microstructure on the corrosion behavior of platinum used for cochlea implant electrodes
Cochlear implants (CIs) have revolutionized the treatment of profound hearing loss, yet their long-term durability remains a challenge due to potential corrosion-induced degradation of the platinum electrodes of the CI. This study examines the corrosion behavior of platinum wires under accelerated test conditions, and compares the results with corrosion patterns observed in explanted CI electrodes from patients after almost 1 year and 26 years. Accelerated corrosion tests with frequencies from 1 to 5 kHz were validated as predictive tools for long-term performance, as the surface morphologies of stimulated platinum wires exhibit notable similarities to those of explanted electrodes. The as-drawn wires analyzed in this study exhibit up to 50 % more corrosion attack than annealed ones. Additionally, the impact of grain orientation on corrosion is examined by testing platinum single crystals with different electrochemical methods. For this purpose, single crystals with the orientation [111], [110] and [100] were analyzed. The research highlights the importance of annealing platinum and minimizing plastic deformation during electrode assembly to enhance electrode durability. Corrosion was found to primarily occur at grain boundaries, with grain orientation showing minimal influence. These findings suggest that engineering grain boundary characteristics could significantly improve the corrosion resistance of polycrystalline electrodes, offering a promising pathway to enhance the longevity of CIs. • Experiments and explants showed similar corrosion, proving their usefulness in predicting long-term in-service behavior. • The as-drawn platinum wires showed more pronounced corrosion attack in all accelerated corrosion tests. • Corrosion attack was most pronounced at the grain boundaries. • Annealed platinum and minimize deformation during assembly to enhance the electrode's longevity.
Authors
- Hans Jürgen Maier (ORCID: https://orcid.org/0000-0003-2119-824X)
- Christian Klose (ORCID: https://orcid.org/0000-0002-5341-8457)
- Sabine Behrens
- D. Canadinç (ORCID: https://orcid.org/0000-0001-9961-7702)
- Martin Ďurišin (ORCID: https://orcid.org/0000-0002-9733-1441)
- Thomas Lenarz
- Tatiana Blank
- E. Lange
Institutions
- Leibniz University Hannover (DE)
- Koç University (TR)
- Medizinische Hochschule Hannover (DE)
- Klinikum Magdeburg (DE)
- University Hospital Magdeburg (DE)
Publication Details
- Journal
- Corrosion Science
- Published
- 2025-01-27
- DOI
- https://doi.org/10.1016/j.corsci.2025.112745
- Citations
- 2
- Primary Topic
- Electrodeposition and Electroless Coatings
- Type
- article
- Field-Weighted Citation Impact
- 1.46
Funders
- Deutsche Forschungsgemeinschaft