Research on power plant security issues monitoring and fault detection using attention based LSTM model

For Photo Voltaic (PV) arrays and Wind systems to operate as efficiently and effectively as possible, fault detection is essential. It is possible to improve the safety of renewable energy systems and guarantee that the service will continue uninterrupted if problem detection and diagnostics are performed in a timely and accurate manner. In general, wind power is one of the three major renewable energy sources, along with solar power and hydropower. Wind power is well distributed around the world, making it suitable to be exploited in human activities for the general welfare of society. A prototype security situational awareness system applicable to the power data communication network service and traffic model should be developed. This will help to successfully enhance the security and service quality of the power data communication network, effectively cope with network security threats in the new environment, and ensure the security of the power plant network access. The traffic of the main network of the existing data communication network will be combined and analyzed, and NQA traffic management algorithms will be studied and proposed. These actions will improve the SLA hierarchical service capability, the service quality of the core services carried by the backbone network, and strengthen the security capability of the new energy power plant communication network access system. For the purpose of this investigation, an attention-based long short-term memory (Att-LSTM) model was used for the categorization of time series actual data. The approach that has been developed is able to identify defects in photovoltaic arrays and inverters, which offers a dependable option for improving the efficiency and dependability of solar energy systems. For the purpose of evaluating the proposed method, a real-world solar energy dataset is used. The findings acquired from this evaluation are compared to the results received from existing detection approaches such as Cryptography, Intrusion Detection System (IDS) methods, and Network Defense Schemes. The results obtained demonstrate that the suggested method surpasses current fault detection techniques, providing greater accuracy and better performance.

Authors

Institutions

Publication Details

Journal
Energy Informatics
Published
2025-01-27
DOI
https://doi.org/10.1186/s42162-025-00473-0
Citations
4
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on power plant security issues monitoring and fault detection using attention based LSTM model

Zeng Dou, Shengda Wang, Danni Liu, Xu Han et al.
4 citations
Energy Informatics
Smart Grid and Power Systems
2.92
article

Research on power plant security issues monitoring and fault detection using attention based LSTM model

Zeng Dou, Shengda Wang, Danni Liu, Xu Han, Ji Du
article en
4 citations

Abstract

For Photo Voltaic (PV) arrays and Wind systems to operate as efficiently and effectively as possible, fault detection is essential. It is possible to improve the safety of renewable energy systems and guarantee that the service will continue uninterrupted if problem detection and diagnostics are performed in a timely and accurate manner. In general, wind power is one of the three major renewable energy sources, along with solar power and hydropower. Wind power is well distributed around the world, making it suitable to be exploited in human activities for the general welfare of society. A prototype security situational awareness system applicable to the power data communication network service and traffic model should be developed. This will help to successfully enhance the security and service quality of the power data communication network, effectively cope with network security threats in the new environment, and ensure the security of the power plant network access. The traffic of the main network of the existing data communication network will be combined and analyzed, and NQA traffic management algorithms will be studied and proposed. These actions will improve the SLA hierarchical service capability, the service quality of the core services carried by the backbone network, and strengthen the security capability of the new energy power plant communication network access system. For the purpose of this investigation, an attention-based long short-term memory (Att-LSTM) model was used for the categorization of time series actual data. The approach that has been developed is able to identify defects in photovoltaic arrays and inverters, which offers a dependable option for improving the efficiency and dependability of solar energy systems. For the purpose of evaluating the proposed method, a real-world solar energy dataset is used. The findings acquired from this evaluation are compared to the results received from existing detection approaches such as Cryptography, Intrusion Detection System (IDS) methods, and Network Defense Schemes. The results obtained demonstrate that the suggested method surpasses current fault detection techniques, providing greater accuracy and better performance.

Energy InformaticsVol. 8(1)
Jilin Electric Power Research Institute (China) (CN)
Openalex Percentile: Top 10%
Smart Grid and Power Systems
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.