Enhanced Intracellular Delivery via a Titanium-Coated TiO<sub>2</sub> Microstructure Device: Leveraging an Infrared Laser for Optimal Efficiency

This study presents a novel optoporation technique using a titanium-coated TiO<sub>2</sub> microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO<sub>2</sub>) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO<sub>2</sub> microstructure (MS). Exposure to the TMS device with an IR diode laser (980 nm) generates heat, forming photothermal bubbles that disrupt the cell membrane and create transient pores for biomolecular delivery. Unlike traditional optoporation methods, which rely on large, vibration-sensitive lasers, the IR diode laser-assisted TMS device-based optoporation technique offers a compact, cost-effective, and portable alternative, making it suitable for clinical and research applications in resource-constrained environments. The performance of the TMS and MS devices was compared in various cancer cell lines (HeLa, L929, and N2a), with the TMS device showing superior delivery success rates for biomolecules of varying molecular sizes. Notably, the TMS device achieved a 99.30% delivery success rate for the smallest molecule, PI dye, and an 85.17% success rate for the largest studied molecule, β-galactosidase enzyme-Cy5. Furthermore, the TMS device consistently provided a higher delivery success rate at lower laser power, minimizing cellular stress and preserving cell survivability. Moreover, using Western Blot analysis, the TMS device demonstrated lower levels of apoptosis compared to the MS device, with statistically significant differences, highlighting its potential for efficient intracellular delivery while minimizing cellular stress and damage. These results highlight the potential of the TMS device as an advanced tool for large-size intracellular biomolecular delivery, offering significant improvements in stability, efficiency, and cell survivability.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-01-27
DOI
https://doi.org/10.1021/acsami.4c17618
Citations
2
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
1.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Intracellular Delivery via a Titanium-Coated TiO2 Microstructure Device: Leveraging an Infrared Laser for Optimal Efficiency

Srabani Kar, Nitish R. Mahapatra, Anand Kumar Patel, Ashwini Shinde et al.
2 citations
ACS Applied Materials & Interfaces
Electrospun Nanofibers in Biomedical Applications
1.19
article

Enhanced Intracellular Delivery via a Titanium-Coated TiO2 Microstructure Device: Leveraging an Infrared Laser for Optimal Efficiency

Srabani Kar, Nitish R. Mahapatra, Anand Kumar Patel, Ashwini Shinde, Tuhin Subhra Santra
article en
2 citations

Abstract

This study presents a novel optoporation technique using a titanium-coated TiO<sub>2</sub> microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO<sub>2</sub>) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO<sub>2</sub> microstructure (MS). Exposure to the TMS device with an IR diode laser (980 nm) generates heat, forming photothermal bubbles that disrupt the cell membrane and create transient pores for biomolecular delivery. Unlike traditional optoporation methods, which rely on large, vibration-sensitive lasers, the IR diode laser-assisted TMS device-based optoporation technique offers a compact, cost-effective, and portable alternative, making it suitable for clinical and research applications in resource-constrained environments. The performance of the TMS and MS devices was compared in various cancer cell lines (HeLa, L929, and N2a), with the TMS device showing superior delivery success rates for biomolecules of varying molecular sizes. Notably, the TMS device achieved a 99.30% delivery success rate for the smallest molecule, PI dye, and an 85.17% success rate for the largest studied molecule, β-galactosidase enzyme-Cy5. Furthermore, the TMS device consistently provided a higher delivery success rate at lower laser power, minimizing cellular stress and preserving cell survivability. Moreover, using Western Blot analysis, the TMS device demonstrated lower levels of apoptosis compared to the MS device, with statistically significant differences, highlighting its potential for efficient intracellular delivery while minimizing cellular stress and damage. These results highlight the potential of the TMS device as an advanced tool for large-size intracellular biomolecular delivery, offering significant improvements in stability, efficiency, and cell survivability.

ACS Applied Materials & InterfacesVol. 17(5)
Indian Institute of Technology Madras (IN), Indian Institute of Technology Hyderabad (IN)
Biotechnology Industry Research Assistance Council
Affordable and clean energy
Openalex Percentile: Top 25%
Electrospun Nanofibers in Biomedical Applications
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.