Optimized PCF architectures for THz detection of aquatic pathogens: Enhancing water quality monitoring

Waterborne bacteria pose a serious hazard to human health, hence a precise detection method is required to identify them. A photonic crystal fiber sensor that takes into account the dangers of aquatic bacteria has been suggested, and its optical characteristics in the THz range have been quantitatively assessed. The PCF sensor was designed and examined as computed in Comsol Multiphysics, a program in which uses the method of "Finite Element Method" (FEM). At 3.2 THz operating frequency, the proposed sensor performs better than the others in all tested cases, with a high sensitivity of 96.78% for Vibrio cholera, 97.54% for E. coli, and 97.40% for Bacillus anthracis. It also has a very low CL of 2.095 × 10-13 dB/cm for Vibrio cholera, 4.411 × 10-11 dB/cm for E. coli, and 1.355 × 10-11 dB/cm for Bacillus anthracis. The existing architecture has the potential to produce the sensor efficiently and scalable, opening the door for commercial applications. The innovation is in the optimization of structural parameters to increase the fiber's sensitivity to bacterial presence, thereby improving the interaction between terahertz waves and bacterial cells. It targets bacterial macromolecule absorption peaks to increase sensitivity. Localized field augmentation, which concentrates THz vibrations where bacteria interact more, may arise from optimization. By improving scattering, structural alterations can help identify bacteria by their characteristic scattering patterns. These improvements improve the sensor's trace bacteria detection. These factors increase the sensor's aquatic germ detection when combined. In aqueous environments, this results in a more precise and efficient detection, which could facilitate the real-time monitoring of bacterial contamination. Public health and water quality control may be significantly affected by these developments.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-01-27
DOI
https://doi.org/10.1371/journal.pone.0317533
Citations
12
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
8.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized PCF architectures for THz detection of aquatic pathogens: Enhancing water quality monitoring

A. H. M. Iftekharul Ferdous, Diponkar Kundu, Md. Galib Hasan, Most. Momtahina Bani et al.
12 citations
PLoS ONE
Terahertz technology and applications
8.77
article

Optimized PCF architectures for THz detection of aquatic pathogens: Enhancing water quality monitoring

A. H. M. Iftekharul Ferdous, Diponkar Kundu, Md. Galib Hasan, Most. Momtahina Bani, Nasir Uddin Badhon, Md. Safiul Islam, Khalid Sifulla Noor
article en
12 citations

Abstract

Waterborne bacteria pose a serious hazard to human health, hence a precise detection method is required to identify them. A photonic crystal fiber sensor that takes into account the dangers of aquatic bacteria has been suggested, and its optical characteristics in the THz range have been quantitatively assessed. The PCF sensor was designed and examined as computed in Comsol Multiphysics, a program in which uses the method of "Finite Element Method" (FEM). At 3.2 THz operating frequency, the proposed sensor performs better than the others in all tested cases, with a high sensitivity of 96.78% for Vibrio cholera, 97.54% for E. coli, and 97.40% for Bacillus anthracis. It also has a very low CL of 2.095 × 10-13 dB/cm for Vibrio cholera, 4.411 × 10-11 dB/cm for E. coli, and 1.355 × 10-11 dB/cm for Bacillus anthracis. The existing architecture has the potential to produce the sensor efficiently and scalable, opening the door for commercial applications. The innovation is in the optimization of structural parameters to increase the fiber's sensitivity to bacterial presence, thereby improving the interaction between terahertz waves and bacterial cells. It targets bacterial macromolecule absorption peaks to increase sensitivity. Localized field augmentation, which concentrates THz vibrations where bacteria interact more, may arise from optimization. By improving scattering, structural alterations can help identify bacteria by their characteristic scattering patterns. These improvements improve the sensor's trace bacteria detection. These factors increase the sensor's aquatic germ detection when combined. In aqueous environments, this results in a more precise and efficient detection, which could facilitate the real-time monitoring of bacterial contamination. Public health and water quality control may be significantly affected by these developments.

PLoS ONEVol. 20(1)
Pabna University of Science and Technology (BD)
Clean water and sanitation
Openalex Percentile: Top 2%
Terahertz technology and applications
8.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.