A Robust Feedback Control Strategy for Parameter Mismatch in Multi-Port Magnetic Network Energy Routers

Multi-Port Magnetic Network Energy Routers (MNER) is a potential topology due to its performance in quick dynamic response, centralize control and improvement of system efficiency. However, the impact of some factors causes parameter mismatch that the performance of model-based control strategies is deteriorated. Although parameter identification is a solution providing precise parameters, it brings extra stress to the compute units. In this paper, a feedback control strategy is proposed that the error of phase-shift is fixed according to the difference between output power and reference power. The proposed strategy is robust to parameter mismatch of inductance itself. Performance of the proposed strategy is analyzed theoretically and the results of simulation verify the effect of this strategy.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/ciycee63099.2024.10846192
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Robust Feedback Control Strategy for Parameter Mismatch in Multi-Port Magnetic Network Energy Routers

Xingyu Zhu, Yuezu Lv, Fujin Deng, Sayed Abulanwar
1 links
Wireless Power Transfer Systems
article

A Robust Feedback Control Strategy for Parameter Mismatch in Multi-Port Magnetic Network Energy Routers

Xingyu Zhu, Yuezu Lv, Fujin Deng, Sayed Abulanwar
article en

Abstract

Multi-Port Magnetic Network Energy Routers (MNER) is a potential topology due to its performance in quick dynamic response, centralize control and improvement of system efficiency. However, the impact of some factors causes parameter mismatch that the performance of model-based control strategies is deteriorated. Although parameter identification is a solution providing precise parameters, it brings extra stress to the compute units. In this paper, a feedback control strategy is proposed that the error of phase-shift is fixed according to the difference between output power and reference power. The proposed strategy is robust to parameter mismatch of inductance itself. Performance of the proposed strategy is analyzed theoretically and the results of simulation verify the effect of this strategy.

Mansoura University (EG), Southeast University (CN)
Science and Technology Development Fund, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 76%
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.