Low-Voltage Ride-Through Method for Grid-Forming Converter Based on Adaptive Virtual Impedance

Due to the good weak grid adaptability and grid support capability, Grid-Forming (GFM) energy storage converter is considered to be an effective solution for the grid-connected interface of new power systems. When a symmetrical low-voltage fault occurring, grid-forming converters may face transient overcurrent problems during the fault and recovery phases. A virtual synchronous generator (VSG)-controlled GFM converter is take as the research object in this paper and a low-voltage ride-through (LVRT) control method of GFM converter is proposed, which realizes the current limitation of GFM converter under low-voltage fault by using adaptive virtual impedance. On the basis of guaranteeing the voltage source characteristics of GFM converter, L VRT control method injects reactive current into the grid according to standards. Finally, based on the Simulink/Matlab simulation platform, the effectiveness of L VRT control method for transient current suppression is verified.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/ciycee63099.2024.10846776
Citations
3
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Voltage Ride-Through Method for Grid-Forming Converter Based on Adaptive Virtual Impedance

Chenxi Bai, Bowen Cui, Changsong Chen, Y. Zhong et al.
3 citations
Power Systems and Renewable Energy
0.51
article

Low-Voltage Ride-Through Method for Grid-Forming Converter Based on Adaptive Virtual Impedance

Chenxi Bai, Bowen Cui, Changsong Chen, Y. Zhong, Taihang He
article en
3 citations

Abstract

Due to the good weak grid adaptability and grid support capability, Grid-Forming (GFM) energy storage converter is considered to be an effective solution for the grid-connected interface of new power systems. When a symmetrical low-voltage fault occurring, grid-forming converters may face transient overcurrent problems during the fault and recovery phases. A virtual synchronous generator (VSG)-controlled GFM converter is take as the research object in this paper and a low-voltage ride-through (LVRT) control method of GFM converter is proposed, which realizes the current limitation of GFM converter under low-voltage fault by using adaptive virtual impedance. On the basis of guaranteeing the voltage source characteristics of GFM converter, L VRT control method injects reactive current into the grid according to standards. Finally, based on the Simulink/Matlab simulation platform, the effectiveness of L VRT control method for transient current suppression is verified.

State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 28%
Power Systems and Renewable Energy
0.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.