ZVS Control For a GaN-Based CRM Totem-Pole PFC Converter With ZCD

This paper presents a detailed analysis of a single-phase GaN-based power factor correction (PFC) critical-conduction-mode (CRM) totem-pole rectifier with zero-voltage-switching (ZVS) control. The paper thoroughly derives the ZVS strategy for full-line periodic zero-voltage switching and introduces a double-closed-loop analytical converter model integrated with a real-time calculation module. A critical aspect of ZVS implementation is the zero-current detection (ZCD) module. Thus, the paper provides a detailed analysis of ZCD signal delays and performs quantitative calculations to compensate for these delays. Both a simulation model and a small power prototype are developed and tested. Experimental results demonstrate that the proposed control strategy effectively achieves CRM totem-pole zero-voltage-switching.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/ciycee63099.2024.10846364
Citations
1
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ZVS Control For a GaN-Based CRM Totem-Pole PFC Converter With ZCD

Hongfa Ding, Zhengyu Lü
1 citations
Advanced DC-DC Converters
0.21
article

ZVS Control For a GaN-Based CRM Totem-Pole PFC Converter With ZCD

Hongfa Ding, Zhengyu Lü
article en
1 citations

Abstract

This paper presents a detailed analysis of a single-phase GaN-based power factor correction (PFC) critical-conduction-mode (CRM) totem-pole rectifier with zero-voltage-switching (ZVS) control. The paper thoroughly derives the ZVS strategy for full-line periodic zero-voltage switching and introduces a double-closed-loop analytical converter model integrated with a real-time calculation module. A critical aspect of ZVS implementation is the zero-current detection (ZCD) module. Thus, the paper provides a detailed analysis of ZCD signal delays and performs quantitative calculations to compensate for these delays. Both a simulation model and a small power prototype are developed and tested. Experimental results demonstrate that the proposed control strategy effectively achieves CRM totem-pole zero-voltage-switching.

Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 44%
Advanced DC-DC Converters
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.