A Novel Denoising Method for Ultra-High Frequency Signals of Partial Discharge in GIS/GIL

Partial discharge (PD) detection is an important means for insulation condition monitoring. The ultra-high frequency (UHF) method is commonly used for on-site PD detection in gas-insulated switchgear (GIS) and gas-insulated transmission line (GIL). However, the obvious attenuation of UHF signal and complex interference result in a low signal-to-noise ratio of PD signals, making it difficult to locate PD source. In this paper, a novel denoising method based on multi-channel correlation-average for UHF PD signals is proposed and displayed. Then, PD detection and localization in a hydropower plant is conducted. The results show that the UHF PD signal (about 5 mV) submerged in noise (about 20 mV) can be effectively extracted using the proposed denoising method. Subsequently, based on the denoised signal, the PD source was accurately located. This further validates the effectiveness of the proposed method. The research of this study provides good guidance for on-site PD detection and equipment maintenance.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/ciycee63099.2024.10846764
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Denoising Method for Ultra-High Frequency Signals of Partial Discharge in GIS/GIL

Wei Li, Zuowei Shen, Gao‐Feng Zhao, Mao Li et al.
High voltage insulation and dielectric phenomena
article

A Novel Denoising Method for Ultra-High Frequency Signals of Partial Discharge in GIS/GIL

Wei Li, Zuowei Shen, Gao‐Feng Zhao, Mao Li, Xing Li, Xinzhi Yang
article en

Abstract

Partial discharge (PD) detection is an important means for insulation condition monitoring. The ultra-high frequency (UHF) method is commonly used for on-site PD detection in gas-insulated switchgear (GIS) and gas-insulated transmission line (GIL). However, the obvious attenuation of UHF signal and complex interference result in a low signal-to-noise ratio of PD signals, making it difficult to locate PD source. In this paper, a novel denoising method based on multi-channel correlation-average for UHF PD signals is proposed and displayed. Then, PD detection and localization in a hydropower plant is conducted. The results show that the UHF PD signal (about 5 mV) submerged in noise (about 20 mV) can be effectively extracted using the proposed denoising method. Subsequently, based on the denoised signal, the PD source was accurately located. This further validates the effectiveness of the proposed method. The research of this study provides good guidance for on-site PD detection and equipment maintenance.

Tsinghua Sichuan Energy Internet Research Institute (CN), Yangtze River Pharmaceutical Group (China) (CN), Tsinghua University (CN)
Openalex Percentile: Top 83%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.