A Constant Power Discharge Strategy for Flywheel Energy Storage System Based on Maximum Torque Per Ampere

Flywheel energy storage system (FESS) possesses advantages such as rapid response, high frequency operation, and long lifespan, making it widely used in grid frequency regulation and uninterrupted power supply. To maintain a stable DC bus voltage during the discharge phase, FESS typically employs an outer-loop DC voltage control on the machine-side converter. However, this control method fails to meet the power response requirements for grid frequency regulation. This study introduces a control strategy that combines outer loop power control with Maximum Torque per Ampere (MTPA) control on the machine-side converter. This approach not only meets the power response requirements but also increases the depth of discharge, thereby fulfilling the needs of grid frequency regulation. Additionally, the grid-side converter utilizes outer loop DC voltage control to ensure DC bus voltage stabilization. The effectiveness of this control strategy is validated through simulation results.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/ciycee63099.2024.10846322
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Constant Power Discharge Strategy for Flywheel Energy Storage System Based on Maximum Torque Per Ampere

Xianfei Xie, Jiahao Xie, Yuanlong Zhao
Power Systems and Renewable Energy
article

A Constant Power Discharge Strategy for Flywheel Energy Storage System Based on Maximum Torque Per Ampere

Xianfei Xie, Jiahao Xie, Yuanlong Zhao
article en

Abstract

Flywheel energy storage system (FESS) possesses advantages such as rapid response, high frequency operation, and long lifespan, making it widely used in grid frequency regulation and uninterrupted power supply. To maintain a stable DC bus voltage during the discharge phase, FESS typically employs an outer-loop DC voltage control on the machine-side converter. However, this control method fails to meet the power response requirements for grid frequency regulation. This study introduces a control strategy that combines outer loop power control with Maximum Torque per Ampere (MTPA) control on the machine-side converter. This approach not only meets the power response requirements but also increases the depth of discharge, thereby fulfilling the needs of grid frequency regulation. Additionally, the grid-side converter utilizes outer loop DC voltage control to ensure DC bus voltage stabilization. The effectiveness of this control strategy is validated through simulation results.

Huazhong University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 71%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Constant Power Discharge Strategy for Flywheel Energy Storage System Based on Maximum Torque Per Ampere — Xianfei Xie, Jiahao Xie, et al. · (2024) | TGRS Research Map | TGRS