IoMT-Enabled Smart-Cap-Powered Ultrawideband Brain Implant for Multichannel Epilepsy Monitoring Applications

Multichannel neural monitoring systems are crucial in the accurate diagnosis and treatment of epilepsy by continuously recording neural activity, allowing precise identification of epileptic zones. These systems demand an ultrawideband (UWB) antenna with wireless power reception capability to facilitate high-data-rate communication and battery-free operation for the development of compact and long-lasting neural devices. This articel introduces a compact (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$9\times 11\times 0$ </tex-math></inline-formula>.25 mm3) battery-free implantable UWB system with an integrated rectifier for multichannel epilepsy monitoring, wirelessly powered by a novel 2.4 GHz smart cap-based transmitter (Tx) antenna. Extensive simulations and measurements are conducted to analyze the system’s performance. The implantable system exhibits a measured ultrawide bandwidth of 6.8 GHz (1.2–8 GHz) with peak gain values of −16.5, −23, and −24.1 dBi at 2.4, 4.8, and 5.8 GHz, respectively. The proposed wearable smart cap-based Tx antenna efficiently transfers power to the UWB implant system in various scenarios, including lateral and rotational misalignments, achieving a measured transmission coefficient <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$(|S_{21}|)$ </tex-math></inline-formula> of −20.06 dB at a 15 mm distance while ensuring user comfort and mobility. Moreover, the compact rectifying circuit achieves a maximum conversion efficiency of 78.4% at a low input power of 6 dBm across a 2 k<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula> load. In addition, the safety of the system was validated using a realistic human head model to ensure compliance with the IEEE specific absorption rate limits. The features and performance metrics demonstrate that the proposed UWB implant system, powered by a wearable smart cap, offers a promising solution for safe, continuous, and battery-free multichannel epilepsy monitoring applications.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2025-01-27
DOI
https://doi.org/10.1109/jiot.2025.3535223
Citations
12
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
17.17
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IoMT-Enabled Smart-Cap-Powered Ultrawideband Brain Implant for Multichannel Epilepsy Monitoring Applications

Abdul Basir, Muhammad Zada, Hyoungsuk Yoo, Izaz Ali Shah
12 citations
IEEE Internet of Things Journal
EEG and Brain-Computer Interfaces
17.17
article

IoMT-Enabled Smart-Cap-Powered Ultrawideband Brain Implant for Multichannel Epilepsy Monitoring Applications

Abdul Basir, Muhammad Zada, Hyoungsuk Yoo, Izaz Ali Shah
article en
12 citations

Abstract

Multichannel neural monitoring systems are crucial in the accurate diagnosis and treatment of epilepsy by continuously recording neural activity, allowing precise identification of epileptic zones. These systems demand an ultrawideband (UWB) antenna with wireless power reception capability to facilitate high-data-rate communication and battery-free operation for the development of compact and long-lasting neural devices. This articel introduces a compact (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$9\times 11\times 0$ </tex-math></inline-formula>.25 mm3) battery-free implantable UWB system with an integrated rectifier for multichannel epilepsy monitoring, wirelessly powered by a novel 2.4 GHz smart cap-based transmitter (Tx) antenna. Extensive simulations and measurements are conducted to analyze the system’s performance. The implantable system exhibits a measured ultrawide bandwidth of 6.8 GHz (1.2–8 GHz) with peak gain values of −16.5, −23, and −24.1 dBi at 2.4, 4.8, and 5.8 GHz, respectively. The proposed wearable smart cap-based Tx antenna efficiently transfers power to the UWB implant system in various scenarios, including lateral and rotational misalignments, achieving a measured transmission coefficient <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$(|S_{21}|)$ </tex-math></inline-formula> of −20.06 dB at a 15 mm distance while ensuring user comfort and mobility. Moreover, the compact rectifying circuit achieves a maximum conversion efficiency of 78.4% at a low input power of 6 dBm across a 2 k<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula> load. In addition, the safety of the system was validated using a realistic human head model to ensure compliance with the IEEE specific absorption rate limits. The features and performance metrics demonstrate that the proposed UWB implant system, powered by a wearable smart cap, offers a promising solution for safe, continuous, and battery-free multichannel epilepsy monitoring applications.

IEEE Internet of Things JournalVol. 12(11)
Tampere University (FI), Shenzhen University (CN), Hanyang University (KR)
Openalex Percentile: Top 1%
EEG and Brain-Computer Interfaces
17.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.