A Fully LTPS-TFT-Based Bidirectional Biomedical Interface Circuit for Large-Area Healthcare Applications

This article proposed a fully low-temperature polysilicon thin-film transistor (LTPS-TFT)-based bidirectional biomedical pixel interface integrated with a high linearity stimulator and a high-performance biopotential sensing front-end circuit to amplify and digitize biological signals for high robustness data transmission. All circuits are designed and manufactured under a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text {3-}\mu \text {m}$ </tex-math></inline-formula> LTPS process. We demonstrated the experiment in saline using the stimulator circuit to simulate stimulation inside the organism, achieving stimulation with different average currents under different duty cycles. The proposed front-end circuit has a gain of 40 dB. The referred input voltage noise of the entire signal chain is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$86.2~\mu \text {V}/\sqrt {\text {Hz}}$ </tex-math></inline-formula>, and the effective number of bits (ENOB) is 9.13 bits at an input of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.5~\text {mV}_{\text {PP}}$ </tex-math></inline-formula>. Simultaneously conducting statistical testing on 20 chips has achieved a 1.05 dB SNDR standard deviation. Finally, we use a function signal generator to simulate the input signals of electrocorticography (ECoG), electrocardiogram (ECG), and electrooculogram (EOG), then use front-end circuits to read and reconstruct them to demonstrate that the proposed pixel interface can correctly read common biomedical signals for healthcare applications.

Authors

Institutions

Publication Details

Journal
IEEE Journal on Flexible Electronics
Published
2024-12-01
DOI
https://doi.org/10.1109/jflex.2025.3534193
Citations
3
Primary Topic
Semiconductor Lasers and Optical Devices
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fully LTPS-TFT-Based Bidirectional Biomedical Interface Circuit for Large-Area Healthcare Applications

Yuqing Lou, Han‐Bo Zhang, Jian Zhao, Fakhrul Zaman Rokhani et al.
3 citations
IEEE Journal on Flexible Electronics
Semiconductor Lasers and Optical Devices
0.63
article

A Fully LTPS-TFT-Based Bidirectional Biomedical Interface Circuit for Large-Area Healthcare Applications

Yuqing Lou, Han‐Bo Zhang, Jian Zhao, Fakhrul Zaman Rokhani, Guoxing Wang, Yongfu Li, Zhihang Zhang
article en
3 citations

Abstract

This article proposed a fully low-temperature polysilicon thin-film transistor (LTPS-TFT)-based bidirectional biomedical pixel interface integrated with a high linearity stimulator and a high-performance biopotential sensing front-end circuit to amplify and digitize biological signals for high robustness data transmission. All circuits are designed and manufactured under a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text {3-}\mu \text {m}$ </tex-math></inline-formula> LTPS process. We demonstrated the experiment in saline using the stimulator circuit to simulate stimulation inside the organism, achieving stimulation with different average currents under different duty cycles. The proposed front-end circuit has a gain of 40 dB. The referred input voltage noise of the entire signal chain is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$86.2~\mu \text {V}/\sqrt {\text {Hz}}$ </tex-math></inline-formula>, and the effective number of bits (ENOB) is 9.13 bits at an input of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.5~\text {mV}_{\text {PP}}$ </tex-math></inline-formula>. Simultaneously conducting statistical testing on 20 chips has achieved a 1.05 dB SNDR standard deviation. Finally, we use a function signal generator to simulate the input signals of electrocorticography (ECoG), electrocardiogram (ECG), and electrooculogram (EOG), then use front-end circuits to read and reconstruct them to demonstrate that the proposed pixel interface can correctly read common biomedical signals for healthcare applications.

IEEE Journal on Flexible ElectronicsVol. 3(12)
Universiti Putra Malaysia (MY), Shanghai Jiao Tong University (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 30%
Semiconductor Lasers and Optical Devices
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.