Direct calibration using atmospheric particles and performance evaluation of Particle Size Magnifier (PSM) 2.0 for sub-10 nm particle measurements

Abstract. The Particle Size Magnifier is widely used for measuring nano-sized particles. Here we calibrated the newly developed Particle Size Magnifier version 2.0 (PSM 2.0). We used 1–10 nm particles with different compositions, including metal particles, organic particles generated in the laboratory, and atmospheric particles collected in Helsinki and Hyytiälä. A noticeable difference among the calibration curves was observed. Atmospheric particles from Hyytiälä required higher diethylene glycol (DEG) supersaturation to be activated compared to metal particles (standard calibration particles) and other types of particles. This suggests that chemical composition differences introduce measurement uncertainties and highlights the importance of in situ calibration. The size resolution of PSM 2.0 was characterized using metal particles. The maximum size resolution was observed at 2–3 nm. PSM 2.0 was then operated in Hyytiälä for ambient particle measurements in parallel with a Half Mini differential mobility particle sizer (DMPS). During new particle formation (NPF) events, comparable total particle concentrations were observed between the Half Mini DMPS and PSM 2.0 based on Hyytiälä atmospheric particle calibration. Meanwhile, applying the calibration with metal particles to atmospheric measurements caused an overestimation of 3–10 nm particles. In terms of the particle size distributions, similar patterns were observed between the DMPS and PSM when using the calibration of Hyytiälä atmospheric particles. In summary, PSM 2.0 is a powerful instrument for measuring sub-10 nm particles and can achieve more precise particle size distribution measurements with proper calibration.

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2025-01-27
DOI
https://doi.org/10.5194/amt-18-431-2025
Citations
2
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
1.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct calibration using atmospheric particles and performance evaluation of Particle Size Magnifier (PSM) 2.0 for sub-10 nm particle measurements

Markku Kulmala, Joonas Enroth, Yiliang Liu, Sebastian Holm et al.
2 citations
Atmospheric measurement techniques
Air Quality Monitoring and Forecasting
1.60
article

Direct calibration using atmospheric particles and performance evaluation of Particle Size Magnifier (PSM) 2.0 for sub-10 nm particle measurements

Markku Kulmala, Joonas Enroth, Yiliang Liu, Sebastian Holm, Juha Kangasluoma, Tommy Chan, Yang Chen, Fabian Schmidt-Ott, Runlong Cai, Lauri Reino Ahonen, Tuukka Petäjä, Joonas Vanhanen, Arttu Yli-Kujala
article en
2 citations

Abstract

Abstract. The Particle Size Magnifier is widely used for measuring nano-sized particles. Here we calibrated the newly developed Particle Size Magnifier version 2.0 (PSM 2.0). We used 1–10 nm particles with different compositions, including metal particles, organic particles generated in the laboratory, and atmospheric particles collected in Helsinki and Hyytiälä. A noticeable difference among the calibration curves was observed. Atmospheric particles from Hyytiälä required higher diethylene glycol (DEG) supersaturation to be activated compared to metal particles (standard calibration particles) and other types of particles. This suggests that chemical composition differences introduce measurement uncertainties and highlights the importance of in situ calibration. The size resolution of PSM 2.0 was characterized using metal particles. The maximum size resolution was observed at 2–3 nm. PSM 2.0 was then operated in Hyytiälä for ambient particle measurements in parallel with a Half Mini differential mobility particle sizer (DMPS). During new particle formation (NPF) events, comparable total particle concentrations were observed between the Half Mini DMPS and PSM 2.0 based on Hyytiälä atmospheric particle calibration. Meanwhile, applying the calibration with metal particles to atmospheric measurements caused an overestimation of 3–10 nm particles. In terms of the particle size distributions, similar patterns were observed between the DMPS and PSM when using the calibration of Hyytiälä atmospheric particles. In summary, PSM 2.0 is a powerful instrument for measuring sub-10 nm particles and can achieve more precise particle size distribution measurements with proper calibration.

Atmospheric measurement techniquesVol. 18(2)
Fudan University (CN), Helsinki Institute of Physics (FI), Helsinki Institute for Information Technology (FI), Chongqing Institute of Green and Intelligent Technology (CN)
National Natural Science Foundation of China, Academy of Finland, Natural Science Foundation of Chongqing, Centre Scientifique et Technique du Bâtiment
Openalex Percentile: Top 21%
Air Quality Monitoring and Forecasting
1.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.