WCN25-930 COMPARATIVE EFFICIENCY OF EXPANDED (HDx) AND HIGH-FLUX HEMODIALYSIS IN THE REMOVAL OF MIDDLE MOLECULES: COREXH-GREEN STUDY

This is the case of a 23-years-old patient, male, who received chronic hemodialysis for two years, he has a history of poor phosphorus management and mild hyperparathyroidism, and no record of hemodialysis complications (see Table No. 1).He was admitted to the emergency department of a highcomplexity hospital, after an impact from a firearm projectile precisely in his left antebrachial arteriovenous fistula, he was immediately taken to surgery with the following findings: segmental venous aneurysmal dilation, a cephalic vein in the distal arm and forearm thrombosed and proximal to the anastomosis with multiple lesions and endothelial compromise.Fistula in brachiocephalic configuration.(See imagine 1, 2 and 3) Surgical procedure: A spindle incision is made over aneurysmal degeneration, vascular planes are identified, dissected by planes until vascular control, aneurysmal degeneration was observed, finding multiple mirror lesions on the posterior and anterior face of the venous segment, with significant tissue injury up to the distal third of the arm.Distal venous ligation is performed, it is dissected caudally until the lateral-terminal anastomosis is identified.The fistula is closed and medium-caliber vessels are repaired with the Carrel modified technique Conclusions: The blood flow from an arteriovenous fistula for hemodialysis is greater than 600ml/min, any injury is potentially lethal if not handled properly.These situations are a challenge for the medical team and a concern for health personnel and security agents I have no potential conflict of interest to disclose.I did not use generative AI and AI-assisted technologies in the writing process.

Authors

Institutions

Publication Details

Journal
Kidney International Reports
Published
2025-01-27
DOI
https://doi.org/10.1016/j.ekir.2024.11.702
Primary Topic
Abdominal vascular conditions and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

WCN25-930 COMPARATIVE EFFICIENCY OF EXPANDED (HDx) AND HIGH-FLUX HEMODIALYSIS IN THE REMOVAL OF MIDDLE MOLECULES: COREXH-GREEN STUDY

Javier Cely, Cesar Mauricio Doria, David Andrés Camargo Mayorga, Ángela Rivera et al.
Kidney International Reports
Abdominal vascular conditions and treatments
article

WCN25-930 COMPARATIVE EFFICIENCY OF EXPANDED (HDx) AND HIGH-FLUX HEMODIALYSIS IN THE REMOVAL OF MIDDLE MOLECULES: COREXH-GREEN STUDY

Javier Cely, Cesar Mauricio Doria, David Andrés Camargo Mayorga, Ángela Rivera, Peter Rutherford, Mauricio Sanabria, Juan Carlos Mario Castillo, Viviana Orozco, Ducuara Daniel
article en

Abstract

This is the case of a 23-years-old patient, male, who received chronic hemodialysis for two years, he has a history of poor phosphorus management and mild hyperparathyroidism, and no record of hemodialysis complications (see Table No. 1).He was admitted to the emergency department of a highcomplexity hospital, after an impact from a firearm projectile precisely in his left antebrachial arteriovenous fistula, he was immediately taken to surgery with the following findings: segmental venous aneurysmal dilation, a cephalic vein in the distal arm and forearm thrombosed and proximal to the anastomosis with multiple lesions and endothelial compromise.Fistula in brachiocephalic configuration.(See imagine 1, 2 and 3) Surgical procedure: A spindle incision is made over aneurysmal degeneration, vascular planes are identified, dissected by planes until vascular control, aneurysmal degeneration was observed, finding multiple mirror lesions on the posterior and anterior face of the venous segment, with significant tissue injury up to the distal third of the arm.Distal venous ligation is performed, it is dissected caudally until the lateral-terminal anastomosis is identified.The fistula is closed and medium-caliber vessels are repaired with the Carrel modified technique Conclusions: The blood flow from an arteriovenous fistula for hemodialysis is greater than 600ml/min, any injury is potentially lethal if not handled properly.These situations are a challenge for the medical team and a concern for health personnel and security agents I have no potential conflict of interest to disclose.I did not use generative AI and AI-assisted technologies in the writing process.

Kidney International ReportsVol. 10(2)
Rafael Advanced Defense Systems (Israel) (IL), Universidad Autónoma de Bucaramanga (CO), Historic Deerfield (US), Intuitive Surgical (Switzerland) (CH), Universidad Nacional de Colombia (CO), Instituto del Corazón de Bucaramanga (CO), Instituto de Salud de Bucaramanga (CO), Instituto Nacional de Cancerología (CO), Stockholm Environment Institute (CO), Institute of Cardiology (CO), Colciencias (CO)
Openalex Percentile: Top 98%
Abdominal vascular conditions and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.