Performance enhancement for stand-alone wind energy conversion system using super-twisting algorithm

This paper presents the super-twisting algorithm (STA) of a permanent magnet synchronous generator (PMSG) associated with a rectifier, a bidirectional DC–DC converter, and an inverter, all controlled by pulse width modulation (PWM). The bidirectional DC–DC converter, which feeds a battery, is controlled to maintain the DC bus voltage at a desired constant value. The purpose of the developed STA is to regulate the d-axis current, monitor the maximum power point, regulate the DC bus voltage by controlling the charge/discharge of a parallel-mounted battery, and regulate the voltage at the load. The STA was studied, and the results obtained were compared with the synergetic control method and the fractional-order PI control method. The results show that the mean value of the THD of the PMSG stator current for the synergetic control is 90.1%, for the FO-PI control is 94.80%, and for the STA is 94.85%; the mean value of the THD of the current at the load terminals is 0.92% for the synergetic control, 1.371% for the FO-PI, and 0.4775% for the STA; the mean value of the THD of the voltage at the load terminals is 1.22% for the synergetic control, 1.618% for the FO-PI, and 0.595% for the STA; the mean value of the relative error in rotational speed is 4.7306e−05 for the synergetic control, 7.9849e−04 for the FO-PI, and 4.5787e−04 for the STA; the mean value of the relative error in d-axis load terminal voltage is 0.0161 for the synergetic control, 0.0035 for the FO-PI, and 0.0023 for the STA; the mean value of the relative error in DC bus voltage is 0.0156 for the synergetic control, 0.0140 for the FO-PI, and 0.0067 for the STA. Simulations performed in the Matlab/Simulink numerical environment demonstrated the effectiveness of the proposed control method when the wind power system is operated under load variations and parameter uncertainties.

Authors

Publication Details

Journal
Energy Reports
Published
2025-01-27
DOI
https://doi.org/10.1016/j.egyr.2025.01.048
Citations
1
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance enhancement for stand-alone wind energy conversion system using super-twisting algorithm

Clotaire Thierry Sanjong Dagang, Godpromesse Kenné, Daniel Borice Tchoumtcha
1 citations
Energy Reports
Wind Turbine Control Systems
0.73
article

Performance enhancement for stand-alone wind energy conversion system using super-twisting algorithm

Clotaire Thierry Sanjong Dagang, Godpromesse Kenné, Daniel Borice Tchoumtcha
article en
1 citations

Abstract

This paper presents the super-twisting algorithm (STA) of a permanent magnet synchronous generator (PMSG) associated with a rectifier, a bidirectional DC–DC converter, and an inverter, all controlled by pulse width modulation (PWM). The bidirectional DC–DC converter, which feeds a battery, is controlled to maintain the DC bus voltage at a desired constant value. The purpose of the developed STA is to regulate the d-axis current, monitor the maximum power point, regulate the DC bus voltage by controlling the charge/discharge of a parallel-mounted battery, and regulate the voltage at the load. The STA was studied, and the results obtained were compared with the synergetic control method and the fractional-order PI control method. The results show that the mean value of the THD of the PMSG stator current for the synergetic control is 90.1%, for the FO-PI control is 94.80%, and for the STA is 94.85%; the mean value of the THD of the current at the load terminals is 0.92% for the synergetic control, 1.371% for the FO-PI, and 0.4775% for the STA; the mean value of the THD of the voltage at the load terminals is 1.22% for the synergetic control, 1.618% for the FO-PI, and 0.595% for the STA; the mean value of the relative error in rotational speed is 4.7306e−05 for the synergetic control, 7.9849e−04 for the FO-PI, and 4.5787e−04 for the STA; the mean value of the relative error in d-axis load terminal voltage is 0.0161 for the synergetic control, 0.0035 for the FO-PI, and 0.0023 for the STA; the mean value of the relative error in DC bus voltage is 0.0156 for the synergetic control, 0.0140 for the FO-PI, and 0.0067 for the STA. Simulations performed in the Matlab/Simulink numerical environment demonstrated the effectiveness of the proposed control method when the wind power system is operated under load variations and parameter uncertainties.

Energy ReportsVol. 13
Affordable and clean energy
Openalex Percentile: Top 32%
Wind Turbine Control Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance enhancement for stand-alone wind energy conversion system using super-twisting algorithm — Clotaire Thierry Sanjong Dagang, Godpromesse Kenné, et al. · Energy Reports (2025) | TGRS Research Map | TGRS