Mitigating dithiothreitol interference to gold/thiol interface in electrochemical detection of cathepsin B activity toward multiplex protease analysis

Proteases are overexpressed at various stages of conditions such as cancers and thus can serve as biomarkers for disease diagnosis. Electrochemical techniques to detect the activity of extracellular proteases have gained attraction due to their multiplexing capability. Here we employ an electrochemical approach based on a 3 × 3 gold (Au) microelectrode array (MEA) functionalized with (2-aminoethyl)ferrocene (AEF) tagged specific peptide substrates to monitor cathepsin B (CB) protease activity. Cleavage of these peptide substrates by proteases leads to an exponential decay in the alternating current voltammetry (ACV) signal. The protease activity is represented by the inverse of the decay time constant (1/τ), which is equal to (k<sub>cat</sub>/K<sub>M</sub>)[CB] based on the heterogeneous Michaelis-Menton model. However, the thiol/Au chemisorption linking AEF-peptide to gold electrodes is susceptible to interference by the protease activation reagent dithiothreitol (DTT), causing the peptides to desorb from the Au surface during continuous ACV measurement. This induces a false signal decay, masking the protease activity and reducing the sensor sensitivity. To address this, DTT is removed after activating CB using centrifugal filtration while EDTA is incorporated to maintain the enzyme activity. This allows accurate CB proteolysis kinetics and clarifies the roles of EDTA and DTT in activation. The intrinsic substrate-dependent cleavage by CB to three different peptide substrates has been demonstrated with the MEA chip, showcasing the potential for rapid activity profiling of multiple proteases. The study highlights the importance of understanding the interference of active bioreagents to the thiol/Au interface in broad redox-tagged electrochemical biosensors.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-01-22
DOI
https://doi.org/10.1016/j.bios.2025.117193
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating dithiothreitol interference to gold/thiol interface in electrochemical detection of cathepsin B activity toward multiplex protease analysis

Lingaraju Gorla, Shunya Morita, Jessica E. Koehne, Morgan J. Anderson et al.
3 citations
Biosensors and Bioelectronics
Advanced biosensing and bioanalysis techniques
2.42
article

Mitigating dithiothreitol interference to gold/thiol interface in electrochemical detection of cathepsin B activity toward multiplex protease analysis

Lingaraju Gorla, Shunya Morita, Jessica E. Koehne, Morgan J. Anderson, Zhaoyang Ren, Bingun T. Perera, Duy H. Hua, Sabari Rajendran, Jun Li, S.-C. Wu
article en
3 citations

Abstract

Proteases are overexpressed at various stages of conditions such as cancers and thus can serve as biomarkers for disease diagnosis. Electrochemical techniques to detect the activity of extracellular proteases have gained attraction due to their multiplexing capability. Here we employ an electrochemical approach based on a 3 × 3 gold (Au) microelectrode array (MEA) functionalized with (2-aminoethyl)ferrocene (AEF) tagged specific peptide substrates to monitor cathepsin B (CB) protease activity. Cleavage of these peptide substrates by proteases leads to an exponential decay in the alternating current voltammetry (ACV) signal. The protease activity is represented by the inverse of the decay time constant (1/τ), which is equal to (k<sub>cat</sub>/K<sub>M</sub>)[CB] based on the heterogeneous Michaelis-Menton model. However, the thiol/Au chemisorption linking AEF-peptide to gold electrodes is susceptible to interference by the protease activation reagent dithiothreitol (DTT), causing the peptides to desorb from the Au surface during continuous ACV measurement. This induces a false signal decay, masking the protease activity and reducing the sensor sensitivity. To address this, DTT is removed after activating CB using centrifugal filtration while EDTA is incorporated to maintain the enzyme activity. This allows accurate CB proteolysis kinetics and clarifies the roles of EDTA and DTT in activation. The intrinsic substrate-dependent cleavage by CB to three different peptide substrates has been demonstrated with the MEA chip, showcasing the potential for rapid activity profiling of multiple proteases. The study highlights the importance of understanding the interference of active bioreagents to the thiol/Au interface in broad redox-tagged electrochemical biosensors.

Biosensors and BioelectronicsVol. 273
Ames Research Center (US), Kansas State University (US), National Research Council Institute for Biodiagnostics (CA)
National Science Foundation, Johnson Cancer Research Center, Kansas State University, National Cancer Institute
Openalex Percentile: Top 13%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.