Effect of Solution Annealing on Corrosion Resistance of Austenitic Stainless Steels in Chloride-Containing Environment

Abstract Austenitic stainless steels are highly corrosion-resistant in common oxidation environments. However, aggressive chloride-containing solutions can evoke local corrosion, which performs an important risk in the safe use of these materials. This research deals with the effect of the solution annealing (1050 °C, 15 min) on the electrochemical parameters of AISI 304 and AISI 316L stainless steels. Corrosion resistance of the solution-annealed specimens is evaluated and compared to the as received specimens by the potentiodynamic polarization test performed in 1M pH neutral NaCl solution at the 20 ± 3 °C temperature. The obtained results did not clearly confirm the positive effect of solution annealing on corrosion resistance in the given aggressive solution. Although the pitting potentials indicating higher pitting corrosion resistance increased, the kinetics of the corrosion process intensified.

Authors

Institutions

Publication Details

Journal
System Safety Human - Technical Facility - Environment
Published
2024-12-01
DOI
https://doi.org/10.2478/czoto-2024-0043
Citations
1
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
0.17

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Solution Annealing on Corrosion Resistance of Austenitic Stainless Steels in Chloride-Containing Environment

Lenka Markovičová, Milan Uhríčik, Viera Zatkalíková, Martin Slezák
1 citations
System Safety Human - Technical Facility - Environment
Hydrogen embrittlement and corrosion behaviors in metals
0.17
article

Effect of Solution Annealing on Corrosion Resistance of Austenitic Stainless Steels in Chloride-Containing Environment

Lenka Markovičová, Milan Uhríčik, Viera Zatkalíková, Martin Slezák
article en
1 citations

Abstract

Abstract Austenitic stainless steels are highly corrosion-resistant in common oxidation environments. However, aggressive chloride-containing solutions can evoke local corrosion, which performs an important risk in the safe use of these materials. This research deals with the effect of the solution annealing (1050 °C, 15 min) on the electrochemical parameters of AISI 304 and AISI 316L stainless steels. Corrosion resistance of the solution-annealed specimens is evaluated and compared to the as received specimens by the potentiodynamic polarization test performed in 1M pH neutral NaCl solution at the 20 ± 3 °C temperature. The obtained results did not clearly confirm the positive effect of solution annealing on corrosion resistance in the given aggressive solution. Although the pitting potentials indicating higher pitting corrosion resistance increased, the kinetics of the corrosion process intensified.

System Safety Human - Technical Facility - EnvironmentVol. 6(1)
University of Žilina (SK)
Slovenská Akadémia Vied, Ministrstvo za Izobraževanje, Znanost in Šport, Kultúrna a Edukacná Grantová Agentúra MŠVVaŠ SR, Vedecká Grantová Agentúra MŠVVaŠ SR a SAV
Openalex Percentile: Top 59%
Hydrogen embrittlement and corrosion behaviors in metals
0.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Solution Annealing on Corrosion Resistance of Austenitic Stainless Steels in Chloride-Containing Environment — Lenka Markovičová, Milan Uhríčik, et al. · System Safety Human - Technical Facility - Environment (2024) | TGRS Research Map | TGRS