Determination of three metabolites of thromboxane A<sub>2</sub> and 8-iso-prostaglandin F<sub>2α</sub> in urine by ultra performance liquid chromatography-tandem mass spectrometry
Thromboxane A<sub>2</sub> (TXA<sub>2</sub>), a prothrombotic factor that induces platelet aggregation and thrombosis, acts as a vasoconstrictor by activating TXA<sub>2</sub> receptors (TP receptors). TXA<sub>2</sub> is extremely unstable and metabolizes into three major metabolites: 2,3-dinor thromboxane B<sub>2</sub> (2,3-dinor-TXB<sub>2</sub>), 11-dehydro TXB<sub>2</sub>(11-dh-TXB<sub>2</sub>), and 11-dehydro-2,3-dinor TXB<sub>2</sub>(11-dh-2,3-dinor-TXB<sub>2</sub>). 8-Iso-prostaglandin F<sub>2α</sub>(8-iso-PGF<sub>2α</sub>), a prostaglandin-like compound widely considered the best biomarker of oxidative stress, can also activate TP receptors. The accurate quantification of TXA<sub>2</sub> metabolites and 8-iso-PGF<sub>2α</sub> is critical in cardiovascular disease (CVD). In this study, a method based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 2,3-dinor-TXB<sub>2</sub>,11-dh-2,3-dinor-TXB<sub>2</sub>, 11-dh-TXB<sub>2</sub>, and 8-iso-PGF<sub>2α</sub> in human urine. Urine samples were collected from healthy volunteers and patients with CT- or MRI-confirmed ischemic stroke occurring less than 48 h earlier, and cryopreserved at -80 ℃ within 1 h after collection. The urine samples were thawed at room temperature and acidified to pH 2.0-4.0 using hydrochloric acid. The supernatant was collected after centrifugation. A total of 1 mL of each urine sample was added with 100 μL of the internal standard working solution and mixed well. The samples were loaded onto a C18 SPE column (50 mg). The SPE cartridges were preconditioned with 500 μL of methanol and then equilibrated with 500 μL of water. After sample loading, the SPE cartridges were washed with 500 μL of water, 500 μL of 5% methanol aqueous solution containing 0.5% (v/v) ammonia, and 500 μL of 5% methanol aqueous solution containing 2% (v/v) formic acid. The cartridges were dried, and the analytes were eluted with 400 μL of methanol. The eluents were dried and subsequently reconstituted with 50 μL of 13% acetonitrile aqueous solution. After filtration through a filter membrane, the samples were analyzed on an ACQUITY UPLC<sup>®</sup> BEH phenyl column (50 mm×2.1 mm, 1.7 μm) via gradient elution using 2 mmol/L ammonium acetate aqueous solution containing 0.002% (v/v) ammonia and acetonitrile as the mobile phases. The flow rate was 0.3 mL/min, and the column temperature was 40 ℃. The analytes were determined in negative electrospray ionization and multiple-reaction monitoring modes. The four target compounds showed satisfactory linearity within the relevant ranges, with linear correlation coefficients (<i>R</i><sup>2</sup>) greater than 0.99. The limits of detection of the method were 0.02 ng/mL for 2,3-dinor-TXB<sub>2</sub> and 0.01 ng/mL for 11-dh-2,3-dinor-TXB<sub>2</sub>, 11-dh-TXB<sub>2</sub>, and 8-iso-PGF<sub>2α</sub>. The limits of quantification were 0.1 ng/mL for 2,3-dinor-TXB<sub>2</sub> and 0.05 ng/mL for 11-dh-2,3-dinor-TXB<sub>2</sub>, 11-dh-TXB<sub>2</sub>, and 8-iso-PGF<sub>2α</sub>. In actual urine, the recovery rates at the LOQ level were in the range of 91.48%-104.87%. The recovery rates at low, medium, and high levels were in the range of 92.95%-104.90%. The intra- and inter-day precisions were in the range of 2.79%-13.01% and 4.45%-13.67%, respectively. The relative error (RE) between the average peak area of the mixed matrix and the sum of the ratios of the pure solution and urine matrices was within ±20%. The samples were stable at 4 ℃ for 24 h and at -70 ℃ for 10 d. The developed method is the first to realize the simultaneous determination of 2,3-dinor-TXB<sub>2</sub>, 11-dh-2,3-dinor-TXB<sub>2</sub>, 11-dh-TXB<sub>2</sub>, and 8-iso-PGF<sub>2α</sub> in urine. The method was used to determine the concentrations of 2,3-dinor-TXB<sub>2</sub>, 11-dh-2,3-dinor-TXB<sub>2</sub>, 11-dh-TXB<sub>2</sub>, and 8-iso-PGF<sub>2α</sub> in healthy controls and patients with ischemic stroke, and the results were corrected using creatinine. Binary logistic regression analysis was used to construct the prediction model, and a receiver operating characteristic (ROC) curve was drawn to evaluate the clinical diagnostic ability of the method for the target compounds. TXA<sub>2</sub> was calculated as the sum of its three metabolites. The area under the curve (AUC) of TXA<sub>2</sub> was 0.849, and the method sensitivity and specificity were 69.2% and 92.3%, respectively. The AUC of 8-iso-PGF<sub>2α</sub> was 0.775, and the method sensitivity and specificity were 84.6% and 76.9%, respectively. The proposed method has good clinical value and is expected to assist in the early screening and diagnosis of ischemic stroke.
Authors
- Xiaoyu Sun (ORCID: https://orcid.org/0000-0002-9468-8787)
- Yun‐Feng Cao (ORCID: https://orcid.org/0000-0002-6625-5765)
- Furong Zhao (ORCID: https://orcid.org/0000-0002-4380-2762)
- Yalian Zhang
- Mengmeng Zhang (ORCID: https://orcid.org/0000-0002-7777-7219)
- Sijia Liu (ORCID: https://orcid.org/0000-0002-4050-3548)
- Kun Hou
Institutions
- Dalian Medical University (CN)
- Jinzhou Medical University (CN)
Publication Details
- Journal
- Chinese Journal of Chromatography
- Published
- 2025-02-01
- DOI
- https://doi.org/10.3724/sp.j.1123.2024.02004
- Primary Topic
- Eicosanoids and Hypertension Pharmacology
- Type
- article
- Field-Weighted Citation Impact
- 0.00