Cerebrovascular Reactivity Mapping in Brain Tumors Based on a Breath‐Hold Task Using Arterial Spin Labeling

Hemodynamic measurements such as cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) can provide useful information for the diagnosis and characterization of brain tumors. Previous work showed that arterial spin labeling (ASL) in combination with vasoactive stimulation enabled simultaneous non-invasive evaluation of both parameters, however this approach had not been previously tested in tumors. The aim of this work was to investigate the application of this technique, using a pseudo-continuous ASL (PCASL) sequence combined with breath-holding at 3 T, to measure CBF and CVR in high-grade gliomas and metastatic lesions, and to explore differences across tumoral-peritumoral regions and tumor types. To that end, 27 patients with brain tumor were studied. Baseline CBF and CVR were measured in tumor, edema, and gray matter (GM) volumes-of-interest (VOIs). Peritumoral ipsilateral ring-shaped VOIs were also generated and mirrored to the contralateral hemisphere. Differences in baseline CBF and CVR were evaluated between contralateral and ipsilateral GM, contralateral and ipsilateral peritumoral rings, and among VOIs and tumor types. CBF in the tumor was higher in grade 4 gliomas than metastases. In grade 4 gliomas, edema had lower CBF than the tumor and contralateral GM. CVR values were different between grade 3 and grade 4 gliomas, and between grade 4 and metastases. CVR values in the tumor were lower compared to the contralateral GM. Differences in CVR between contralateral and ipsilateral-ring VOIs were also found in grade 4 gliomas, presumably suggesting tumor infiltration within the peritumoral tissue. A cut-off value for CVR of 27.9%-signal-change is suggested to differentiate between grade 3 and grade 4 gliomas (specificity = 83.3%, sensitivity = 70.6%). In conclusion, CBF and CVR mapping with ASL offered insights into the perilesional environment that could help to detect infiltrative disease, particularly in grade 4 gliomas. CVR emerged as a potential biomarker to differentiate between grade 3 and grade 4 gliomas.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-01-22
DOI
https://doi.org/10.1002/nbm.5317
Citations
4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
5.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cerebrovascular Reactivity Mapping in Brain Tumors Based on a Breath‐Hold Task Using Arterial Spin Labeling

María A. Fernández‐Seara, Marta Calvo‐Imirizaldu, Elena Cacho‐Asenjo, Sergio Solis-Barquero et al.
4 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
5.44
article

Cerebrovascular Reactivity Mapping in Brain Tumors Based on a Breath‐Hold Task Using Arterial Spin Labeling

María A. Fernández‐Seara, Marta Calvo‐Imirizaldu, Elena Cacho‐Asenjo, Sergio Solis-Barquero, José I. Echeveste, Bartolomé Bejarano, Pablo Domínguez, Verónica Aramendía‐Vidaurreta, Allan Argueta, Marta Vidorreta, Antonio Martínez-Simón
article en
4 citations

Abstract

Hemodynamic measurements such as cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) can provide useful information for the diagnosis and characterization of brain tumors. Previous work showed that arterial spin labeling (ASL) in combination with vasoactive stimulation enabled simultaneous non-invasive evaluation of both parameters, however this approach had not been previously tested in tumors. The aim of this work was to investigate the application of this technique, using a pseudo-continuous ASL (PCASL) sequence combined with breath-holding at 3 T, to measure CBF and CVR in high-grade gliomas and metastatic lesions, and to explore differences across tumoral-peritumoral regions and tumor types. To that end, 27 patients with brain tumor were studied. Baseline CBF and CVR were measured in tumor, edema, and gray matter (GM) volumes-of-interest (VOIs). Peritumoral ipsilateral ring-shaped VOIs were also generated and mirrored to the contralateral hemisphere. Differences in baseline CBF and CVR were evaluated between contralateral and ipsilateral GM, contralateral and ipsilateral peritumoral rings, and among VOIs and tumor types. CBF in the tumor was higher in grade 4 gliomas than metastases. In grade 4 gliomas, edema had lower CBF than the tumor and contralateral GM. CVR values were different between grade 3 and grade 4 gliomas, and between grade 4 and metastases. CVR values in the tumor were lower compared to the contralateral GM. Differences in CVR between contralateral and ipsilateral-ring VOIs were also found in grade 4 gliomas, presumably suggesting tumor infiltration within the peritumoral tissue. A cut-off value for CVR of 27.9%-signal-change is suggested to differentiate between grade 3 and grade 4 gliomas (specificity = 83.3%, sensitivity = 70.6%). In conclusion, CBF and CVR mapping with ASL offered insights into the perilesional environment that could help to detect infiltrative disease, particularly in grade 4 gliomas. CVR emerged as a potential biomarker to differentiate between grade 3 and grade 4 gliomas.

NMR in BiomedicineVol. 38(3)
Navarre Institute of Health Research (ES), Clinica Universidad de Navarra (ES), Siemens (Spain) (ES)
Ministerio de Ciencia e Innovación, Universidad de Costa Rica, Fundación Carolina, Instituto de Salud Carlos III
Good health and well-being
Openalex Percentile: Top 5%
Advanced MRI Techniques and Applications
5.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.