Correlation of Dual-Energy X-Ray Absorptiometry and Quantitative Computerized Tomography in Detection of Osteoporosis among Postmenopausal Women

Osteoporosis is a serious health responsibility for clinicians, especially in postmenopausal patients. Dual-energy x-ray absorptiometry is currently the gold standard for the detection of osteoporosis, though its accuracy may be compromised due to concomitant degenerative changes. Objectives: To find out the detection rate of osteoporosis in women who have gone through menopause using both dual-energy X-ray absorptiometry and quantitative computerized tomography and to identify correlations between the two. To evaluate quantitative computerized tomography as a possible future imaging modality that can address the constraints of dual-energy x-ray absorptiometry. Methods: From June 2016 to July 2017, this cross-sectional study was carried out in the radiology Departments of Capital Hospital and Nuclear Medicine, Oncology and Radiotherapy Institute Hospital, Islamabad. With informed consent, seventy postmenopausal women participated. T-scores were calculated for quantitative computerized tomography and dual-energy x-ray absorptiometry, and data analysis, including the Pearson correlation coefficient, was conducted using SPSS-17. Results: The study included postmenopausal women aged 45–70, with menopause lasting over two years. The mean T-scores for quantitative computerized tomography and dual-energy x-ray absorptiometry were -2.4 ± 1.4 SD and -2.1 ± 1.3 SD, respectively. A strong positive correlation was established between quantitative computerized tomography and dual-energy x-ray absorptiometry T-scores (r=0.808; p<0.05). Conclusions: It was concluded that the study showed a constructive association between the T-scores obtained using quantitative computerized tomography and dual-energy x-ray absorptiometry, thus suggesting that quantitative computerized tomography can be used as an alternative to dual-energy x-ray absorptiometry in the detection of osteoporosis.

Authors

Institutions

Publication Details

Journal
Pakistan Journal of Health Sciences
Published
2024-12-31
DOI
https://doi.org/10.54393/pjhs.v5i12.1811
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation of Dual-Energy X-Ray Absorptiometry and Quantitative Computerized Tomography in Detection of Osteoporosis among Postmenopausal Women

Humaira Riaz, Saba Binte Kashmir, Shazia Yusuf, Romasa Zeb et al.
Pakistan Journal of Health Sciences
Bone health and osteoporosis research
article

Correlation of Dual-Energy X-Ray Absorptiometry and Quantitative Computerized Tomography in Detection of Osteoporosis among Postmenopausal Women

Humaira Riaz, Saba Binte Kashmir, Shazia Yusuf, Romasa Zeb, Muhammad Afzal Abbasi, Rana Muhammad Haseeb Kamran
article en

Abstract

Osteoporosis is a serious health responsibility for clinicians, especially in postmenopausal patients. Dual-energy x-ray absorptiometry is currently the gold standard for the detection of osteoporosis, though its accuracy may be compromised due to concomitant degenerative changes. Objectives: To find out the detection rate of osteoporosis in women who have gone through menopause using both dual-energy X-ray absorptiometry and quantitative computerized tomography and to identify correlations between the two. To evaluate quantitative computerized tomography as a possible future imaging modality that can address the constraints of dual-energy x-ray absorptiometry. Methods: From June 2016 to July 2017, this cross-sectional study was carried out in the radiology Departments of Capital Hospital and Nuclear Medicine, Oncology and Radiotherapy Institute Hospital, Islamabad. With informed consent, seventy postmenopausal women participated. T-scores were calculated for quantitative computerized tomography and dual-energy x-ray absorptiometry, and data analysis, including the Pearson correlation coefficient, was conducted using SPSS-17. Results: The study included postmenopausal women aged 45–70, with menopause lasting over two years. The mean T-scores for quantitative computerized tomography and dual-energy x-ray absorptiometry were -2.4 ± 1.4 SD and -2.1 ± 1.3 SD, respectively. A strong positive correlation was established between quantitative computerized tomography and dual-energy x-ray absorptiometry T-scores (r=0.808; p<0.05). Conclusions: It was concluded that the study showed a constructive association between the T-scores obtained using quantitative computerized tomography and dual-energy x-ray absorptiometry, thus suggesting that quantitative computerized tomography can be used as an alternative to dual-energy x-ray absorptiometry in the detection of osteoporosis.

Pakistan Journal of Health Sciences
Rawalpindi Medical University (PK), Lahore General Hospital (PK), Farooq Hospital (PK), Capital University of Science and Technology (PK), Army Medical College (PK)
Openalex Percentile: Top 65%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.