Three Phase PLL for Grid Tied Power Converter Applications

In this study, we have implemented a full model of three-phase Phase-Locked Loop (PLL) based on MATLAB Simulink for grid-connected power converter systems. After the PLL, measured voltages are processed by a set of Clarke and Park transformations to retrieve DC steady-state values that can be used to adjust the phase output from an asynchronous concerning an input three-phase signal The PLECS simulation shows the way from input signals all the way to phase angle generation and constant adaptation for optimal synchronization. To interface with the F28069M DSP kit, signal conditionalization is achieved using a summing amplifier and center-tapped step-down transformer in hardware configuration. It has perfect phase synchronization which is required for power electronics and control systems.

Authors

Institutions

Publication Details

Published
2024-12-20
DOI
https://doi.org/10.1109/innova63080.2024.10847002
Citations
1
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three Phase PLL for Grid Tied Power Converter Applications

A. B. Raju, Srushti B. Rajamani, Spoorti N. Pattanashetti, Tunga S. Kulakarni et al.
1 citations
Microgrid Control and Optimization
0.33
article

Three Phase PLL for Grid Tied Power Converter Applications

A. B. Raju, Srushti B. Rajamani, Spoorti N. Pattanashetti, Tunga S. Kulakarni, Laxmi M. Arer
article en
1 citations

Abstract

In this study, we have implemented a full model of three-phase Phase-Locked Loop (PLL) based on MATLAB Simulink for grid-connected power converter systems. After the PLL, measured voltages are processed by a set of Clarke and Park transformations to retrieve DC steady-state values that can be used to adjust the phase output from an asynchronous concerning an input three-phase signal The PLECS simulation shows the way from input signals all the way to phase angle generation and constant adaptation for optimal synchronization. To interface with the F28069M DSP kit, signal conditionalization is achieved using a summing amplifier and center-tapped step-down transformer in hardware configuration. It has perfect phase synchronization which is required for power electronics and control systems.

KLE Technological University (IN)
Affordable and clean energy
Openalex Percentile: Top 37%
Microgrid Control and Optimization
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.