UPPER–STRUCTURE ANALYSIS OF BTS TOWER ON HIGH WIND SPEED AREA

Media transmission (Telcom) tower could be a media transmission building structure that employments a combination of steel outlines as its development fabric. Media transmission towers work as a back for a few media transmission types of gear for transmitting signals that back the cellular communication frameworks that we continuously utilize so remote. Communication. In tower planning, the prevailing powerful stack is wind stack since wind may be a sidelong stack that encompasses a tall affectability to steel development buildings (incorporates a mass that tends to be light). The tallness of the tower that's made depends on the area of the tower itself. The most issue in this inquire about is how to dissect the tower upper–structure in arrange to determine whether it is solid or not to preserve Wind load analysis on BTS (Base Transceiver Station) towers is one of the important aspects in the design of telecommunication tower structures. Wind load can affect the stability and strength of the tower, mainly due to the height of the tower and the nature of the load which tends to change according to the wind speed and the shape of the tower. Study in this research will is about ”Upper–Structure Analysis of Bts Tower on High Wind Speed Area” as a solution to the problems that often occur in the field and until now still often appear structural infeasibility in the selection of construction systems for BTS Tower planning. Results for anlaysis for each joints are : Anchor Bolt Dimensions : 32 mm X 130 cm X 9 units ; Base Plate Dimensions : 50 cm X 50 cm X 32 mm ; Bolts Dimensions for Anchor Joint Type 1 : 16 mm X 40 mm X 5 units ; Bolts Dimensions for Anchor Joint Type 2 : 16 mm X 40 mm X 4 units ; olts Dimensions for Anchor Joint Type 3 : 16 mm X 40 mm X 5 units ; Bolts Dimensions for Anchor Joint Type 4 : 16 mm X 40 mm X 2 units ; Bolts Dimensions for Anchor Joint Type 5 : 16 mm X 40 mm X 2 units ; Bolts Dimensions for Anchor Joint Type 6 : 16 mm X 40 mm X 2 units ; Couple Plate Dimensions : 60 cm ; Bolts Dimension : L 200 X 15 + L 80 x 8.

Authors

Institutions

Publication Details

Journal
DEARSIP Journal of Architecture and Civil
Published
2024-11-30
DOI
https://doi.org/10.52166/dearsip.v4i02.7800
Citations
1
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UPPER–STRUCTURE ANALYSIS OF BTS TOWER ON HIGH WIND SPEED AREA

Julius Mulyono, Heru Setiyo Cahyono, Annisa' Carina, Mochammad Hendy Wicaksono
1 citations
DEARSIP Journal of Architecture and Civil
Vibration and Dynamic Analysis
0.33
article

UPPER–STRUCTURE ANALYSIS OF BTS TOWER ON HIGH WIND SPEED AREA

Julius Mulyono, Heru Setiyo Cahyono, Annisa' Carina, Mochammad Hendy Wicaksono
article en
1 citations

Abstract

Media transmission (Telcom) tower could be a media transmission building structure that employments a combination of steel outlines as its development fabric. Media transmission towers work as a back for a few media transmission types of gear for transmitting signals that back the cellular communication frameworks that we continuously utilize so remote. Communication. In tower planning, the prevailing powerful stack is wind stack since wind may be a sidelong stack that encompasses a tall affectability to steel development buildings (incorporates a mass that tends to be light). The tallness of the tower that's made depends on the area of the tower itself. The most issue in this inquire about is how to dissect the tower upper–structure in arrange to determine whether it is solid or not to preserve Wind load analysis on BTS (Base Transceiver Station) towers is one of the important aspects in the design of telecommunication tower structures. Wind load can affect the stability and strength of the tower, mainly due to the height of the tower and the nature of the load which tends to change according to the wind speed and the shape of the tower. Study in this research will is about ”Upper–Structure Analysis of Bts Tower on High Wind Speed Area” as a solution to the problems that often occur in the field and until now still often appear structural infeasibility in the selection of construction systems for BTS Tower planning. Results for anlaysis for each joints are : Anchor Bolt Dimensions : 32 mm X 130 cm X 9 units ; Base Plate Dimensions : 50 cm X 50 cm X 32 mm ; Bolts Dimensions for Anchor Joint Type 1 : 16 mm X 40 mm X 5 units ; Bolts Dimensions for Anchor Joint Type 2 : 16 mm X 40 mm X 4 units ; olts Dimensions for Anchor Joint Type 3 : 16 mm X 40 mm X 5 units ; Bolts Dimensions for Anchor Joint Type 4 : 16 mm X 40 mm X 2 units ; Bolts Dimensions for Anchor Joint Type 5 : 16 mm X 40 mm X 2 units ; Bolts Dimensions for Anchor Joint Type 6 : 16 mm X 40 mm X 2 units ; Couple Plate Dimensions : 60 cm ; Bolts Dimension : L 200 X 15 + L 80 x 8.

DEARSIP Journal of Architecture and CivilVol. 4(02)
Karunya University (IN), Universitas Katolik Widya Mandala Surabaya (ID), Darul Ulum Islamic University (ID)
Openalex Percentile: Top 37%
Vibration and Dynamic Analysis
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.