Quantitative Evaluation of a Deep Learning-based U-Net Model for Denoising Lung CT Images

This study explores the efficacy of the U-Net architecture for denoising lung CT images that have undergone the introduction of artificially added Gaussian noise. Noise in medical imaging can significantly compromise diagnostic accuracy, prompting the utilization of U-Net to mitigate this challenge. We set the noise standard deviations of 0.03, 0.05, and 0.07, employing metrics such as Mean Squared Error (MSE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), and skewness and kurtosis of patch-based statistics difference across a dataset of 100 CT DICOM files. The results exhibited substantial enhancements in evaluating metrics following denoising, underscoring the model's capability to effectively alleviate noise and enhance diagnostic reliability. Despite positive evaluation metric results, blurring effects led to the loss of anatomical information, demonstrating the necessity for further advancements in denoising techniques. This research provides a foundational framework for the development of robust methodologies aimed at improving the quality of medical imaging.

Authors

Publication Details

Journal
Journal of Magnetics
Published
2024-12-31
DOI
https://doi.org/10.4283/jmag.2024.29.4.550
Citations
1
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Evaluation of a Deep Learning-based U-Net Model for Denoising Lung CT Images

Chan-Young Park, Byungdu Jo
1 citations
Journal of Magnetics
Radiomics and Machine Learning in Medical Imaging
0.40
article

Quantitative Evaluation of a Deep Learning-based U-Net Model for Denoising Lung CT Images

Chan-Young Park, Byungdu Jo
article en
1 citations

Abstract

This study explores the efficacy of the U-Net architecture for denoising lung CT images that have undergone the introduction of artificially added Gaussian noise. Noise in medical imaging can significantly compromise diagnostic accuracy, prompting the utilization of U-Net to mitigate this challenge. We set the noise standard deviations of 0.03, 0.05, and 0.07, employing metrics such as Mean Squared Error (MSE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), and skewness and kurtosis of patch-based statistics difference across a dataset of 100 CT DICOM files. The results exhibited substantial enhancements in evaluating metrics following denoising, underscoring the model's capability to effectively alleviate noise and enhance diagnostic reliability. Despite positive evaluation metric results, blurring effects led to the loss of anatomical information, demonstrating the necessity for further advancements in denoising techniques. This research provides a foundational framework for the development of robust methodologies aimed at improving the quality of medical imaging.

Journal of MagneticsVol. 29(4)
Openalex Percentile: Top 31%
Radiomics and Machine Learning in Medical Imaging
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative Evaluation of a Deep Learning-based U-Net Model for Denoising Lung CT Images — Chan-Young Park, Byungdu Jo · Journal of Magnetics (2024) | TGRS Research Map | TGRS