Dose Analysis of Reproductive Organs during Abdomen Radiography for Childbearing Age’s Women: Simulation and Actual data based

Abdominal radiography is one of the most radiographs in medical institutions. Therefore, this study aims to confirm the effect of dose reduction using shielding, focusing on measuring the radiation dose to each organ of women of childbearing age. The actual dose was defined as the average value of entrance surface dose (ESD) using a dosimeter. The simulation design for dose comparison of each organ was performed using MCNP program with HDRK-Women phantom. As a shielding method, 0.25, 0.5, and 0.75 mm Pb were applied to calculate the shielding rate for each condition. The actual measured average exposure doses were 9.69, 2.14, and 1.07 μSv, respectively (All p<0.05), and the simulation dose were 11.1, 2.54, and 1.21 μSv, respectively. Under shielding conditions, the effect of dose reduction was confirmed by 98.99% (Actual : 99.35%, Simulation : 98.63%).

Authors

Publication Details

Journal
Journal of Magnetics
Published
2024-12-31
DOI
https://doi.org/10.4283/jmag.2024.29.4.495
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dose Analysis of Reproductive Organs during Abdomen Radiography for Childbearing Age’s Women: Simulation and Actual data based

Man-Seok Han, J M Park, Sangtae Ahn, Young Seok Ji et al.
Journal of Magnetics
Radiation Dose and Imaging
article

Dose Analysis of Reproductive Organs during Abdomen Radiography for Childbearing Age’s Women: Simulation and Actual data based

Man-Seok Han, J M Park, Sangtae Ahn, Young Seok Ji, Jie Yang, Chang-Min Dae
article en

Abstract

Abdominal radiography is one of the most radiographs in medical institutions. Therefore, this study aims to confirm the effect of dose reduction using shielding, focusing on measuring the radiation dose to each organ of women of childbearing age. The actual dose was defined as the average value of entrance surface dose (ESD) using a dosimeter. The simulation design for dose comparison of each organ was performed using MCNP program with HDRK-Women phantom. As a shielding method, 0.25, 0.5, and 0.75 mm Pb were applied to calculate the shielding rate for each condition. The actual measured average exposure doses were 9.69, 2.14, and 1.07 μSv, respectively (All p<0.05), and the simulation dose were 11.1, 2.54, and 1.21 μSv, respectively. Under shielding conditions, the effect of dose reduction was confirmed by 98.99% (Actual : 99.35%, Simulation : 98.63%).

Journal of MagneticsVol. 29(4)
Gender equality
Openalex Percentile: Top 57%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.