Self-calibrated single-wavelength biosensor for measuring SpO2

Arterial oxygen saturation (SpO<sub>2</sub>), a key indicator of respiratory health, reflects the proportion of oxygenated hemoglobin in the blood and is essential for monitoring conditions such as hypoxia. Traditional pulse oximetry methods use multiple wavelengths to calculate SpO<sub>2</sub>, which cause errors due to differences in optical pathlengths, affected by different scattering coefficients. This study presents an optical biosensor for non-invasive measurement of SpO<sub>2</sub>, utilizing the iso-pathlength (IPL) point concept. Our biosensor overcomes the inherent limitations of the classic method by using a single light source and detecting reemitted light at the IPL point, where light intensity is invariant to scattering. This enables accurate SpO<sub>2</sub> measurements without the need for external calibration. The biosensor operates with a red LED at 655nm and five photodetectors, one positioned at the IPL point, which allows the extraction of absorption coefficients from which a PPG signal can be derived. Previous work showed an error of 0.4%, demonstrating the biosensor’s accuracy. In this work we tested 43 subjects by placing the biosensor on the inner side of their upper arms, a location commonly used for blood pressure measurement. The SpO<sub>2</sub> values ranged from 95.2% to 100.3%, with an average of 99.3%.

Authors

Publication Details

Published
2025-01-23
DOI
https://doi.org/10.1117/12.3044285
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-calibrated single-wavelength biosensor for measuring SpO2

Hamootal Duadi, Dror Fixler, Michal Katan
1 citations
Analytical Chemistry and Sensors
0.74
article

Self-calibrated single-wavelength biosensor for measuring SpO2

Hamootal Duadi, Dror Fixler, Michal Katan
article en
1 citations

Abstract

Arterial oxygen saturation (SpO<sub>2</sub>), a key indicator of respiratory health, reflects the proportion of oxygenated hemoglobin in the blood and is essential for monitoring conditions such as hypoxia. Traditional pulse oximetry methods use multiple wavelengths to calculate SpO<sub>2</sub>, which cause errors due to differences in optical pathlengths, affected by different scattering coefficients. This study presents an optical biosensor for non-invasive measurement of SpO<sub>2</sub>, utilizing the iso-pathlength (IPL) point concept. Our biosensor overcomes the inherent limitations of the classic method by using a single light source and detecting reemitted light at the IPL point, where light intensity is invariant to scattering. This enables accurate SpO<sub>2</sub> measurements without the need for external calibration. The biosensor operates with a red LED at 655nm and five photodetectors, one positioned at the IPL point, which allows the extraction of absorption coefficients from which a PPG signal can be derived. Previous work showed an error of 0.4%, demonstrating the biosensor’s accuracy. In this work we tested 43 subjects by placing the biosensor on the inner side of their upper arms, a location commonly used for blood pressure measurement. The SpO<sub>2</sub> values ranged from 95.2% to 100.3%, with an average of 99.3%.

Affordable and clean energy
Openalex Percentile: Top 39%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.