Study on Smoke Leakage Performance in Mass Timber Construction Taking Cross-Laminated Timber Walls as an Example

In contemporary building design, partition walls combined with doors and windows are commonly used to control the spread of smoke. Understanding the smoke leakage characteristics of cross-laminated timber (CLT) walls is crucial for enhancing safety. This study investigates the smoke-sealing performance of CLT walls through full-scale tests, focusing on the application of this type of mass timber construction in smoke control. The test specimens included four joints, with leakage measured under two conditions—non-fire and fire exposure—at three different pressure differentials. A total of 72 tests were conducted. The results showed that under non-fire conditions, the leakage rate was 0.00 m3/h, while exposure to fire caused a significant increase in leakage. Under a pressure differential of 25 Pa, the average leakage rate was 8.17 m3/h, with a maximum of 8.27 m3/h. This study also proposes a method for evaluating the leakage rate of a single joint, which helps estimate the smoke layer descent time and, in turn, the allowable evacuation time. The findings not only enhance the fire safety performance of mass timber construction but also provide valuable insights for evacuation planning.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-01-23
DOI
https://doi.org/10.3390/fire8020042
Citations
1
Primary Topic
Urban and spatial planning
Type
article
Field-Weighted Citation Impact
2.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Smoke Leakage Performance in Mass Timber Construction Taking Cross-Laminated Timber Walls as an Example

Wen-Yao Chang, Meng-Ting Tsai, Ying-Ji Chuang, Ching‐Yuan Lin
1 citations
Fire
Urban and spatial planning
2.31
article

Study on Smoke Leakage Performance in Mass Timber Construction Taking Cross-Laminated Timber Walls as an Example

Wen-Yao Chang, Meng-Ting Tsai, Ying-Ji Chuang, Ching‐Yuan Lin
article en
1 citations

Abstract

In contemporary building design, partition walls combined with doors and windows are commonly used to control the spread of smoke. Understanding the smoke leakage characteristics of cross-laminated timber (CLT) walls is crucial for enhancing safety. This study investigates the smoke-sealing performance of CLT walls through full-scale tests, focusing on the application of this type of mass timber construction in smoke control. The test specimens included four joints, with leakage measured under two conditions—non-fire and fire exposure—at three different pressure differentials. A total of 72 tests were conducted. The results showed that under non-fire conditions, the leakage rate was 0.00 m3/h, while exposure to fire caused a significant increase in leakage. Under a pressure differential of 25 Pa, the average leakage rate was 8.17 m3/h, with a maximum of 8.27 m3/h. This study also proposes a method for evaluating the leakage rate of a single joint, which helps estimate the smoke layer descent time and, in turn, the allowable evacuation time. The findings not only enhance the fire safety performance of mass timber construction but also provide valuable insights for evacuation planning.

FireVol. 8(2)
National Taiwan University of Science and Technology (TW)
Openalex Percentile: Top 17%
Urban and spatial planning
2.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.