Research on anti-interference technology of groundwater heavy metal fluorescence detection device

Heavy metals in liquid seriously harm the environment and threaten human health. The fluorescence detection system based on fluorescence probe method has the advantages of small size and fast detection speed, which is helpful to understand the pollution status and environmental risk of groundwater and provide scientific basis for liquid environment treatment. However, long time laser irradiation of fluorescent probe produces photobleaching phenomenon, which weakens the fluorescence signal intensity. The excitation noise in the confocal detection optical path is high, resulting in low signal-to-noise ratio, which cannot meet the requirement of high sensitivity detection. In this paper, the anti-interference technology of groundwater heavy metal fluorescence detection device is studied. The effect of photobleaching and optical noise is avoided by single pulse excitation and noise reduction using dichroic mirror. After applying the improvement, the repeatability error is reduced from 1.59% to 0.23%, while the noise is reduced by 87.5%. The stability of the detection results and the signal-to-noise ratio are significantly improved, so the anti-interference ability of detection device is greatly enhanced.

Authors

Institutions

Publication Details

Published
2025-01-22
DOI
https://doi.org/10.1117/12.3055650
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on anti-interference technology of groundwater heavy metal fluorescence detection device

Guanghui Wang, Pei Zhang, Bin Chen, Bowen Sun et al.
Water Quality Monitoring and Analysis
article

Research on anti-interference technology of groundwater heavy metal fluorescence detection device

Guanghui Wang, Pei Zhang, Bin Chen, Bowen Sun, Jing Zhu
article en

Abstract

Heavy metals in liquid seriously harm the environment and threaten human health. The fluorescence detection system based on fluorescence probe method has the advantages of small size and fast detection speed, which is helpful to understand the pollution status and environmental risk of groundwater and provide scientific basis for liquid environment treatment. However, long time laser irradiation of fluorescent probe produces photobleaching phenomenon, which weakens the fluorescence signal intensity. The excitation noise in the confocal detection optical path is high, resulting in low signal-to-noise ratio, which cannot meet the requirement of high sensitivity detection. In this paper, the anti-interference technology of groundwater heavy metal fluorescence detection device is studied. The effect of photobleaching and optical noise is avoided by single pulse excitation and noise reduction using dichroic mirror. After applying the improvement, the repeatability error is reduced from 1.59% to 0.23%, while the noise is reduced by 87.5%. The stability of the detection results and the signal-to-noise ratio are significantly improved, so the anti-interference ability of detection device is greatly enhanced.

Shanghai Institute of Optics and Fine Mechanics (CN), University of Chinese Academy of Sciences (CN)
Clean water and sanitation
Openalex Percentile: Top 99%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on anti-interference technology of groundwater heavy metal fluorescence detection device — Guanghui Wang, Pei Zhang, et al. · (2025) | TGRS Research Map | TGRS