Creation of Positive and Zero Sequence Equivalent Circuit Models for Three-Winding Transformers

To calculate short circuit currents correctly and to make protection and coordination settings, it is important to measure the positive and zero sequence impedances of power transformers, which are indispensable elements of the power system. In this study, the measurements and mathematical operations performed to obtain the positive and zero sequence impedance models of three-phase transformers obtained from three-winding single-phase transformers are explained in detail. For the verification studies of the positive and zero sequence impedance equivalent circuit model of the single-phase 1 kVA, 276/120/54 V, mantel type, YNyn+d connection group test transformer, phase-ground fault was experimentally carried out in Kocaeli University Facility Research and Application Unit Laboratory. Model verification studies were supported by performing phase-ground fault in MATLAB/SIMULINK environment. Phase-ground fault solution was performed with symmetrical components by replacing the transformer equivalent circuit obtained from positive and zero sequence measurement results. The obtained equivalent circuit model was verified with simulation study and experimental measurements.

Authors

Publication Details

Published
2024-11-28
DOI
https://doi.org/10.1109/eleco64362.2024.10847182
Citations
2
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Creation of Positive and Zero Sequence Equivalent Circuit Models for Three-Winding Transformers

Bora Alboyacı, Bilal Canol, Rukiye BAYMAZ
2 citations
Induction Heating and Inverter Technology
0.43
article

Creation of Positive and Zero Sequence Equivalent Circuit Models for Three-Winding Transformers

Bora Alboyacı, Bilal Canol, Rukiye BAYMAZ
article en
2 citations

Abstract

To calculate short circuit currents correctly and to make protection and coordination settings, it is important to measure the positive and zero sequence impedances of power transformers, which are indispensable elements of the power system. In this study, the measurements and mathematical operations performed to obtain the positive and zero sequence impedance models of three-phase transformers obtained from three-winding single-phase transformers are explained in detail. For the verification studies of the positive and zero sequence impedance equivalent circuit model of the single-phase 1 kVA, 276/120/54 V, mantel type, YNyn+d connection group test transformer, phase-ground fault was experimentally carried out in Kocaeli University Facility Research and Application Unit Laboratory. Model verification studies were supported by performing phase-ground fault in MATLAB/SIMULINK environment. Phase-ground fault solution was performed with symmetrical components by replacing the transformer equivalent circuit obtained from positive and zero sequence measurement results. The obtained equivalent circuit model was verified with simulation study and experimental measurements.

Affordable and clean energy
Openalex Percentile: Top 40%
Induction Heating and Inverter Technology
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.