Digital Implementation of Discontinuous PWMs: Mitigating Parasitic Active Vectors for Improved Load Current Quality in Inverter Systems

Discontinuous PWM (DPWM) strategies are widely used in voltage-source inverters (VSIs) due to reduced switching losses and improved harmonic performance at higher modulation indexes. However, DPWMs with discontinuous zero-sequence signals (ZSS) can cause current spikes at clamping instants, which depend on the modulation index and load parameters. In the literature, this behavior is often attributed to the rapid changes in ZSS. This article demonstrates that the current spikes are primarily caused by improper modulator implementation on digital signal processors (DSPs), which introduces an unintended active vector instead of a zero vector at the end of a positive bus clamp for a given phase. The issue arises because PWM modules operate as set-reset units based on a timer and compare values, unlike analog comparators, which react instantaneously. We propose a simple solution using an auxiliary compare register, which is effective for most DSPs. The solution's effectiveness is demonstrated on a VSI-fed 12-kW induction machine controlled by a C2000 Texas Instruments DSP.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-01-22
DOI
https://doi.org/10.1109/tpel.2025.3532744
Citations
1
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital Implementation of Discontinuous PWMs: Mitigating Parasitic Active Vectors for Improved Load Current Quality in Inverter Systems

Filip Baum, Jan Bauer, Ondrej Lipcak, Jakub Kucera
1 citations
IEEE Transactions on Power Electronics
Multilevel Inverters and Converters
0.73
article

Digital Implementation of Discontinuous PWMs: Mitigating Parasitic Active Vectors for Improved Load Current Quality in Inverter Systems

Filip Baum, Jan Bauer, Ondrej Lipcak, Jakub Kucera
article en
1 citations

Abstract

Discontinuous PWM (DPWM) strategies are widely used in voltage-source inverters (VSIs) due to reduced switching losses and improved harmonic performance at higher modulation indexes. However, DPWMs with discontinuous zero-sequence signals (ZSS) can cause current spikes at clamping instants, which depend on the modulation index and load parameters. In the literature, this behavior is often attributed to the rapid changes in ZSS. This article demonstrates that the current spikes are primarily caused by improper modulator implementation on digital signal processors (DSPs), which introduces an unintended active vector instead of a zero vector at the end of a positive bus clamp for a given phase. The issue arises because PWM modules operate as set-reset units based on a timer and compare values, unlike analog comparators, which react instantaneously. We propose a simple solution using an auxiliary compare register, which is effective for most DSPs. The solution's effectiveness is demonstrated on a VSI-fed 12-kW induction machine controlled by a C2000 Texas Instruments DSP.

IEEE Transactions on Power ElectronicsVol. 40(5)
Czech Technical University in Prague (CZ)
Affordable and clean energy
Openalex Percentile: Top 32%
Multilevel Inverters and Converters
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Digital Implementation of Discontinuous PWMs: Mitigating Parasitic Active Vectors for Improved Load Current Quality in Inverter Systems — Filip Baum, Jan Bauer, et al. · IEEE Transactions on Power Electronics (2025) | TGRS Research Map | TGRS