A Low Detection Limit and High Sensitivity Three-Dimensional Structured X-Ray Detector

A novel and highly sensitive X-ray detector with three-dimensional structured electrodes (3D-SiC) has been prepared on a high-resistivity silicon carbide substrate. The detector consistently demonstrates a low leakage current of 7.1 pA and 280 pA with the bias of 200 V at room temperature and 150°C, respectively. In the X-ray response test, the 3D-SiC detector exhibits high sensitivity of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${5}.{65}\times {10} ^{{4}}~\mu $ </tex-math></inline-formula>C<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> Gy<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$_{\text {air}}^{-{1}}\cdot $ </tex-math></inline-formula>cm<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{2}}$ </tex-math></inline-formula>. Meanwhile, it exhibits a linear response to dose rates ranging from 0.67 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.02~\mu $ </tex-math></inline-formula>Gy<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$_{\text {air}}\cdot $ </tex-math></inline-formula>s<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>. So, the detection limit could be calculated as low as 6.92 nGy<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$_{\text {air}}\cdot $ </tex-math></inline-formula>s<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>. Comparing with planar semiconductor-based X-ray detectors, 3D-SiC detector shows ultra-high sensitivity with extremely low detection limit at room temperature. This characteristic renders it potentially advantageous in domains characterized by limited X-ray detection and imaging capabilities, such as the field of X-ray medical diagnosis.

Authors

Institutions

Publication Details

Journal
IEEE Electron Device Letters
Published
2025-01-22
DOI
https://doi.org/10.1109/led.2025.3532677
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low Detection Limit and High Sensitivity Three-Dimensional Structured X-Ray Detector

Hongwei Liang, Ruirui Fan, Guosheng Ji, Wei Jiang et al.
2 citations
IEEE Electron Device Letters
Medical Imaging Techniques and Applications
2.72
article

A Low Detection Limit and High Sensitivity Three-Dimensional Structured X-Ray Detector

Hongwei Liang, Ruirui Fan, Guosheng Ji, Wei Jiang, Xiaochuan Xia, Deyu Wang, Ruiliang Xu, X. Shi, Yang Liu, Xingzhu Cui, Hongyun Wang, Ziyang Han
article en
2 citations

Abstract

A novel and highly sensitive X-ray detector with three-dimensional structured electrodes (3D-SiC) has been prepared on a high-resistivity silicon carbide substrate. The detector consistently demonstrates a low leakage current of 7.1 pA and 280 pA with the bias of 200 V at room temperature and 150°C, respectively. In the X-ray response test, the 3D-SiC detector exhibits high sensitivity of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${5}.{65}\times {10} ^{{4}}~\mu $ </tex-math></inline-formula>C<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> Gy<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$_{\text {air}}^{-{1}}\cdot $ </tex-math></inline-formula>cm<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{2}}$ </tex-math></inline-formula>. Meanwhile, it exhibits a linear response to dose rates ranging from 0.67 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.02~\mu $ </tex-math></inline-formula>Gy<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$_{\text {air}}\cdot $ </tex-math></inline-formula>s<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>. So, the detection limit could be calculated as low as 6.92 nGy<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$_{\text {air}}\cdot $ </tex-math></inline-formula>s<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>. Comparing with planar semiconductor-based X-ray detectors, 3D-SiC detector shows ultra-high sensitivity with extremely low detection limit at room temperature. This characteristic renders it potentially advantageous in domains characterized by limited X-ray detection and imaging capabilities, such as the field of X-ray medical diagnosis.

IEEE Electron Device LettersVol. 46(3)
Chinese Academy of Sciences (CN), Dalian University of Technology (CN), Institute of High Energy Physics (CN)
National Natural Science Foundation of China, Natural Science Foundation of Liaoning Province, Fundamental Research Funds for the Central Universities, Dalian Science and Technology Innovation Fund
Affordable and clean energy
Openalex Percentile: Top 13%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.