Novel Artificial Biosensor Based on Molecular Imprinting Technology for Recognition and Label-Free Electrochemical Detection of <i>Staphylococcus aureus</i>

In the present research endeavor, a sensor utilizing an imprinted polymer film was developed to detect Staphylococcus aureus in biological samples and contaminated foodstuffs. To achieve this objective, an imprinted polymer film containing the bacteria was synthesized via electropolymerization on a glassy carbon electrode (GCE). Subsequently, the modifications in the characteristics of the working electrode were examined using scanning electron microscopy (SEM). The determination of S. aureus was conducted under optimal conditions, employing [Fe(CN)6]<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{\text {3-/ {4}-}}$ </tex-math></inline-formula> as a redox probe, utilizing the differential pulse voltammetry (DPV) technique within a linear range of 10 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5\times 10^{{8}}$ </tex-math></inline-formula> CFU<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> mL<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>, with a detection limit established at 2.7 CFU<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> mL<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>. In addition, the sensor’s repeatability, stability, and selectivity were assessed in the presence of interfering bacteria. The results of this investigation indicated that the proposed electrode exhibits commendable repeatability, selectivity, and stability.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-01-22
DOI
https://doi.org/10.1109/jsen.2025.3530142
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Artificial Biosensor Based on Molecular Imprinting Technology for Recognition and Label-Free Electrochemical Detection of Staphylococcus aureus

Karim Asadpour‐Zeynali, Masoud Moghadaszadeh, Elhameh Saeb, Sahar Ghadimipour
IEEE Sensors Journal
Biosensors and Analytical Detection
article

Novel Artificial Biosensor Based on Molecular Imprinting Technology for Recognition and Label-Free Electrochemical Detection of Staphylococcus aureus

Karim Asadpour‐Zeynali, Masoud Moghadaszadeh, Elhameh Saeb, Sahar Ghadimipour
article en

Abstract

In the present research endeavor, a sensor utilizing an imprinted polymer film was developed to detect Staphylococcus aureus in biological samples and contaminated foodstuffs. To achieve this objective, an imprinted polymer film containing the bacteria was synthesized via electropolymerization on a glassy carbon electrode (GCE). Subsequently, the modifications in the characteristics of the working electrode were examined using scanning electron microscopy (SEM). The determination of S. aureus was conducted under optimal conditions, employing [Fe(CN)6]<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{\text {3-/ {4}-}}$ </tex-math></inline-formula> as a redox probe, utilizing the differential pulse voltammetry (DPV) technique within a linear range of 10 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5\times 10^{{8}}$ </tex-math></inline-formula> CFU<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> mL<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>, with a detection limit established at 2.7 CFU<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> mL<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>. In addition, the sensor’s repeatability, stability, and selectivity were assessed in the presence of interfering bacteria. The results of this investigation indicated that the proposed electrode exhibits commendable repeatability, selectivity, and stability.

IEEE Sensors JournalVol. 25(5)
Tabriz University of Medical Sciences (IR), University of Tabriz (IR), Biotechnology Research Center (IR)
University of Tabriz
Openalex Percentile: Top 99%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.