Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: Technical Air

This article investigates the effect of aging due to free-burning arcs on the dielectric performance and the chemical composition of technical air (79% N2 and 21% O2) at 1.3-bar absolute pressure. The aging is performed by exposing the gas to a series of arcs dissipating an accumulated energy of more than 300 kJ, a level corresponding to relevant arcing energies for medium-voltage (MV) load break switches. To evaluate the long-term dielectric performance, lightning impulse (LI) and power frequency AC breakdown tests are conducted in a 10-mm rod–plane gap before and after aging. Gas decomposition is also investigated with gas chromatography coupled with mass spectrometry (GC–MS). Results indicate that the LI breakdown voltage of air may enhance temporarily after arcing. This is probably due to the formation of short-lived air byproducts (e.g., NO, NO2, NO3, and O3) which may reduce initial electron generation. However, changes in AC breakdown voltage might not be that significant as the presence of primary electrons is presumably guaranteed in the latter case.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-01-22
DOI
https://doi.org/10.1109/tdei.2025.3532882
Citations
1
Primary Topic
Vehicle emissions and performance
Type
article
Field-Weighted Citation Impact
0.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: Technical Air

Cédric Lesaint, Frank Mauseth, Marte Gammelsæter, Nina Sasaki Støa-Aanensen et al.
1 citations
IEEE Transactions on Dielectrics and Electrical Insulation
Vehicle emissions and performance
0.68
article

Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: Technical Air

Cédric Lesaint, Frank Mauseth, Marte Gammelsæter, Nina Sasaki Støa-Aanensen, Arik Subhana
article en
1 citations

Abstract

This article investigates the effect of aging due to free-burning arcs on the dielectric performance and the chemical composition of technical air (79% N2 and 21% O2) at 1.3-bar absolute pressure. The aging is performed by exposing the gas to a series of arcs dissipating an accumulated energy of more than 300 kJ, a level corresponding to relevant arcing energies for medium-voltage (MV) load break switches. To evaluate the long-term dielectric performance, lightning impulse (LI) and power frequency AC breakdown tests are conducted in a 10-mm rod–plane gap before and after aging. Gas decomposition is also investigated with gas chromatography coupled with mass spectrometry (GC–MS). Results indicate that the LI breakdown voltage of air may enhance temporarily after arcing. This is probably due to the formation of short-lived air byproducts (e.g., NO, NO2, NO3, and O3) which may reduce initial electron generation. However, changes in AC breakdown voltage might not be that significant as the presence of primary electrons is presumably guaranteed in the latter case.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 32(3)
SINTEF (NO), Norwegian University of Science and Technology (NO)
Norges Forskningsråd
Life in Land
Openalex Percentile: Top 35%
Vehicle emissions and performance
0.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.