High precision adjustable current limit protection circuit for power protection switches

In order to improve the flexibility of the current protection circuit operation, a current protection circuit that can change the current limit value by adjusting the resistance value of the external resistor is designed. The load current is sampled using a sense-FET sensing circuit designed with an improved common-source common-gate current mirror, which reduces losses while ensuring the accuracy of the current limit value. The current is processed through two different branches to improve the efficiency of fault handling. The design is implemented using a 0.18 μm BCD process. Simulation results show that at a supply voltage of 12 V, current limit range of 1 A~5 A, the accuracy is less than 0.96% affected by temperature, the fast shutdown time is about 70 ns, and the completion of the protection time is about 1 μs.

Authors

Institutions

Publication Details

Journal
IEICE Electronics Express
Published
2025-01-22
DOI
https://doi.org/10.1587/elex.22.20240589
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High precision adjustable current limit protection circuit for power protection switches

Xianguo Cao, H. Ren
IEICE Electronics Express
Electrical Contact Performance and Analysis
article

High precision adjustable current limit protection circuit for power protection switches

Xianguo Cao, H. Ren
article en

Abstract

In order to improve the flexibility of the current protection circuit operation, a current protection circuit that can change the current limit value by adjusting the resistance value of the external resistor is designed. The load current is sampled using a sense-FET sensing circuit designed with an improved common-source common-gate current mirror, which reduces losses while ensuring the accuracy of the current limit value. The current is processed through two different branches to improve the efficiency of fault handling. The design is implemented using a 0.18 μm BCD process. Simulation results show that at a supply voltage of 12 V, current limit range of 1 A~5 A, the accuracy is less than 0.96% affected by temperature, the fast shutdown time is about 70 ns, and the completion of the protection time is about 1 μs.

IEICE Electronics ExpressVol. 22(5)
Sichuan University of Science and Engineering (CN)
Sichuan University of Science and Engineering, Sichuan University
Affordable and clean energy
Openalex Percentile: Top 99%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.