Effect of contaminant particles, temperature, and humidity on the dielectric strength of insulating oils

In this work, the behavior of the dielectric breakdown voltage of insulating oils concerning variations in temperature, humidity, and contaminant concentration was established. Tests used electrodes for flat, spherical, and Verband Deutscher Elektrotechniker (VDE) type. The influence of contaminant concentration (cellulose, iron, and copper), humidity, and temperature on the breakdown voltage of the oils was determined through a four-level experimental design. Data collected in the tests were analyzed using Analysis Of Variance (ANOVA). The experimental phase of the research was carried out in the High Voltage Laboratory of Unidades Tecnológicas de Santander. The most relevant results showed that the contaminant concentration is inversely related to the oil breakdown voltage, with copper being the material with the most significant influence on the study variable. Likewise, temperature is directly related to the breakdown voltage level, with the highest levels reached when the test is conducted at 90 °C. For the three types of electrodes used, it is shown that humidity has an inverse relationship with breakdown voltage. In all cases, the highest disruption values are achieved with a moisture of 5 ppm. • Factors such as temperature, humidity, and the concentration of contaminants significantly influence performance. • Among contaminants, copper has the most pronounced negative effect on the breakdown voltage of oil. • Breakdown voltage tends to increase with higher temperatures, reaching its maximum at 90 °C. • The study emphasizes the critical role of controlling temperature, humidity, and contaminant levels in transformer oils to preserve their dielectric strength in practical applications.

Authors

Institutions

Publication Details

Journal
Journal of Electrostatics
Published
2025-01-22
DOI
https://doi.org/10.1016/j.elstat.2025.104030
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of contaminant particles, temperature, and humidity on the dielectric strength of insulating oils

O. Sánchez, Jaime Alfonso Gil Lozano, Fabio Alfonso González, A. Retamoso et al.
1 citations
Journal of Electrostatics
High voltage insulation and dielectric phenomena
0.52
article

Effect of contaminant particles, temperature, and humidity on the dielectric strength of insulating oils

O. Sánchez, Jaime Alfonso Gil Lozano, Fabio Alfonso González, A. Retamoso, F. Cely
article en
1 citations

Abstract

In this work, the behavior of the dielectric breakdown voltage of insulating oils concerning variations in temperature, humidity, and contaminant concentration was established. Tests used electrodes for flat, spherical, and Verband Deutscher Elektrotechniker (VDE) type. The influence of contaminant concentration (cellulose, iron, and copper), humidity, and temperature on the breakdown voltage of the oils was determined through a four-level experimental design. Data collected in the tests were analyzed using Analysis Of Variance (ANOVA). The experimental phase of the research was carried out in the High Voltage Laboratory of Unidades Tecnológicas de Santander. The most relevant results showed that the contaminant concentration is inversely related to the oil breakdown voltage, with copper being the material with the most significant influence on the study variable. Likewise, temperature is directly related to the breakdown voltage level, with the highest levels reached when the test is conducted at 90 °C. For the three types of electrodes used, it is shown that humidity has an inverse relationship with breakdown voltage. In all cases, the highest disruption values are achieved with a moisture of 5 ppm. • Factors such as temperature, humidity, and the concentration of contaminants significantly influence performance. • Among contaminants, copper has the most pronounced negative effect on the breakdown voltage of oil. • Breakdown voltage tends to increase with higher temperatures, reaching its maximum at 90 °C. • The study emphasizes the critical role of controlling temperature, humidity, and contaminant levels in transformer oils to preserve their dielectric strength in practical applications.

Journal of ElectrostaticsVol. 134
Unidades Tecnológicas de Santander (CO)
Openalex Percentile: Top 43%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of contaminant particles, temperature, and humidity on the dielectric strength of insulating oils — O. Sánchez, Jaime Alfonso Gil Lozano, et al. · Journal of Electrostatics (2025) | TGRS Research Map | TGRS