Monolithic U-shaped crystal design for TOF-DOI detectors: a flat top versus a tapered top

For brain-dedicated positron emission tomography (PET) scanners, depth-of-interaction (DOI) information is essential to achieve uniform spatial resolution across the field-of-view (FOV) by minimizing parallax error. Time-of-flight (TOF) information can enhance the image quality. In this study, we proposed a novel monolithic U-shaped crystal design that had a tapered geometry to achieve good coincidence timing resolution (CTR) and DOI resolution simultaneously. We compared a novel tapered U-shaped crystal design with a conventional flat-top geometry for PET detectors. Each crystal had outer dimensions of 5.85 × 2.75 × 15 mm<sup>3</sup>, with a 0.2 mm central gap forming physically isolated bottom surfaces (2.85 × 2.75 mm<sup>2</sup>). The novel U-shape crystal design with a tapered top roof resulted in the best CTR of 201 ± 3 ps, and DOI resolution of 3.1 ± 0.6 mm, which were better than flat top geometry. In the next study, we plan to optimize the crystal surface treatment and reflector to further improve the CTR and DOI resolution.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-01-22
DOI
https://doi.org/10.1088/2057-1976/adaced
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monolithic U-shaped crystal design for TOF-DOI detectors: a flat top versus a tapered top

Miho Kiyokawa, Han Gyu Kang, Taiga Yamaya
2 citations
Biomedical Physics & Engineering Express
Medical Imaging Techniques and Applications
2.72
article

Monolithic U-shaped crystal design for TOF-DOI detectors: a flat top versus a tapered top

Miho Kiyokawa, Han Gyu Kang, Taiga Yamaya
article en
2 citations

Abstract

For brain-dedicated positron emission tomography (PET) scanners, depth-of-interaction (DOI) information is essential to achieve uniform spatial resolution across the field-of-view (FOV) by minimizing parallax error. Time-of-flight (TOF) information can enhance the image quality. In this study, we proposed a novel monolithic U-shaped crystal design that had a tapered geometry to achieve good coincidence timing resolution (CTR) and DOI resolution simultaneously. We compared a novel tapered U-shaped crystal design with a conventional flat-top geometry for PET detectors. Each crystal had outer dimensions of 5.85 × 2.75 × 15 mm<sup>3</sup>, with a 0.2 mm central gap forming physically isolated bottom surfaces (2.85 × 2.75 mm<sup>2</sup>). The novel U-shape crystal design with a tapered top roof resulted in the best CTR of 201 ± 3 ps, and DOI resolution of 3.1 ± 0.6 mm, which were better than flat top geometry. In the next study, we plan to optimize the crystal surface treatment and reflector to further improve the CTR and DOI resolution.

Biomedical Physics & Engineering ExpressVol. 11(2)
Chiba University (JP), National Institutes for Quantum Science and Technology (JP), Chiba Hospital (JP)
Japan Agency for Medical Research and Development, Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering
Sustainable cities and communities
Openalex Percentile: Top 13%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.