Optical Simulation Study for Non-Invasive Jaundice Application: Effect of Bilirubin, Melanosome, LED Radial Width Distribution and Optode Distance

One of the promising diagnosis devices is the non-invasive bilirubin detection for estimating newborn jaundice. From the light interaction through tissue perspective, less attention has been given to the effect of LED radial width distribution at different melanosome content and bilirubin concentrations. Besides, different optode (emitter-detector) spacing can affect the light measured at the detector. This paper aims to investigate the effects of three LED radial width distributions (30°, 40° and 60°) on three types of skin pigmentation (light-skinned Caucasians, well-tanned Caucasians and Mediterranean, and dark-skinned pigmented Africans) based on hyperbilirubinemia and excessive hyperbilirubinemia conditions by using MCmatlab to simulate a 3D cuboid shape of neonatal forehead tissue layers. To mimic the tissues model, optical properties such as absorption coefficient (μ_a), reduced scattering coefficient (〖'μ〗_s), and scattering anisotropy (g) were applied in every layer. Wavelength 470 nm was chosen since it is the most responsive wavelength at bilirubin’s absorption spectra. Two optode spacing (0.7 cm and 2 cm) were used to demonstrate the effect of LED radial width. Main findings revealed that for all three types of skin, 30° LED radial width distribution resulted different trends in 0.7 cm and 2 cm of optode spacing. At 0.7 cm, a higher percentage of incident light was collected at the detector, whereas diffuse reflectance was lower. However, at a 2cm distance, both diffuse reflectance and the percentage of incident light collected on the detector were lower. These measured outcomes in diffuse reflectance on light skin were increased by six times, and the incident light collected was one time larger than on tanned and dark skin, as light skin colour absorbs less light and therefore gives a better reflection. Different optode spacing will be investigated for future studies as this information can serve as valuable input when designing optical hardware for non-invasive jaundice detection.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Applied Sciences and Engineering Technology
Published
2024-10-07
DOI
https://doi.org/10.37934/araset.55.1.177190
Primary Topic
Neonatal Health and Biochemistry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Simulation Study for Non-Invasive Jaundice Application: Effect of Bilirubin, Melanosome, LED Radial Width Distribution and Optode Distance

J. Ali, Wan Mahani Hafizah Wan Mahmud, Audrey Huong, Nur Safwah Abd Rahaman et al.
Journal of Advanced Research in Applied Sciences and Engineering Technology
Neonatal Health and Biochemistry
article

Optical Simulation Study for Non-Invasive Jaundice Application: Effect of Bilirubin, Melanosome, LED Radial Width Distribution and Optode Distance

J. Ali, Wan Mahani Hafizah Wan Mahmud, Audrey Huong, Nur Safwah Abd Rahaman, Nur Anida Jumadi
article en

Abstract

One of the promising diagnosis devices is the non-invasive bilirubin detection for estimating newborn jaundice. From the light interaction through tissue perspective, less attention has been given to the effect of LED radial width distribution at different melanosome content and bilirubin concentrations. Besides, different optode (emitter-detector) spacing can affect the light measured at the detector. This paper aims to investigate the effects of three LED radial width distributions (30°, 40° and 60°) on three types of skin pigmentation (light-skinned Caucasians, well-tanned Caucasians and Mediterranean, and dark-skinned pigmented Africans) based on hyperbilirubinemia and excessive hyperbilirubinemia conditions by using MCmatlab to simulate a 3D cuboid shape of neonatal forehead tissue layers. To mimic the tissues model, optical properties such as absorption coefficient (μ_a), reduced scattering coefficient (〖'μ〗_s), and scattering anisotropy (g) were applied in every layer. Wavelength 470 nm was chosen since it is the most responsive wavelength at bilirubin’s absorption spectra. Two optode spacing (0.7 cm and 2 cm) were used to demonstrate the effect of LED radial width. Main findings revealed that for all three types of skin, 30° LED radial width distribution resulted different trends in 0.7 cm and 2 cm of optode spacing. At 0.7 cm, a higher percentage of incident light was collected at the detector, whereas diffuse reflectance was lower. However, at a 2cm distance, both diffuse reflectance and the percentage of incident light collected on the detector were lower. These measured outcomes in diffuse reflectance on light skin were increased by six times, and the incident light collected was one time larger than on tanned and dark skin, as light skin colour absorbs less light and therefore gives a better reflection. Different optode spacing will be investigated for future studies as this information can serve as valuable input when designing optical hardware for non-invasive jaundice detection.

Journal of Advanced Research in Applied Sciences and Engineering TechnologyVol. 55(1)
COMSATS University Islamabad (PK), Tun Hussein Onn University of Malaysia (MY)
Universiti Tun Hussein Onn Malaysia
Openalex Percentile: Top 60%
Neonatal Health and Biochemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.