Remote Deep-Ultraviolet Laser Ablation in Connection with Electrospray Ionization–Atmospheric Pressure Chemical Ionization (rDUVLAESCI): A Novel Dual Ionization Source for Molecular Mass Spectrometry

A novel remote deep ultraviolet laser ablation inlet connected to a dual electrospray ionization-atmospheric pressure chemical ionization (rDUVLAESCI) source is presented. This system allows for the simultaneous and spatial acquisition of mass spectrometry (MS) data for organic molecules with diverse polarities and molecular weights. Deep 193 nm UV laser ablation was used to sample analytes from dried spots for molecular MS analysis precisely. Furthermore, molecular MS imaging (MSI) with a variable laser spot size down to 3 μm was demonstrated. The complementary ionization modes generated mass spectra with sufficient analyte signals, detecting a broad range of molecules from polar compounds like caffeine and PEG 600, to nonpolar analytes, such as anthracene and wax esters, all within a single analytical run. Detection limits were found in the tens of attomoles per ablated/desorbed pixel. The powerful capabilities of the fully automated rDUVLAESCI dual source were demonstrated by visualizing the spatial distribution of new psychoactive substances on latent fingerprints. MSI for both sebum components and psychoactive substances revealed a connection between the chemical evidence and biometrical information. The rDUVLAESCI-MSI enabled the unambiguous identification of individuals, even using partially overlapped latent fingerprints. This unique rDUVLAESCI approach, with its remote laser ablation unit, improved spatial resolution and analyte coverage, particularly for nonpolar compounds.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-01-22
DOI
https://doi.org/10.1021/acs.analchem.4c04392
Citations
2
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remote Deep-Ultraviolet Laser Ablation in Connection with Electrospray Ionization–Atmospheric Pressure Chemical Ionization (rDUVLAESCI): A Novel Dual Ionization Source for Molecular Mass Spectrometry

Barbora Papoušková, Tomáš Pluháček, Petr Fryčák, Karel Lemr et al.
2 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
1.51
article

Remote Deep-Ultraviolet Laser Ablation in Connection with Electrospray Ionization–Atmospheric Pressure Chemical Ionization (rDUVLAESCI): A Novel Dual Ionization Source for Molecular Mass Spectrometry

Barbora Papoušková, Tomáš Pluháček, Petr Fryčák, Karel Lemr, Filip Gregar
article en
2 citations

Abstract

A novel remote deep ultraviolet laser ablation inlet connected to a dual electrospray ionization-atmospheric pressure chemical ionization (rDUVLAESCI) source is presented. This system allows for the simultaneous and spatial acquisition of mass spectrometry (MS) data for organic molecules with diverse polarities and molecular weights. Deep 193 nm UV laser ablation was used to sample analytes from dried spots for molecular MS analysis precisely. Furthermore, molecular MS imaging (MSI) with a variable laser spot size down to 3 μm was demonstrated. The complementary ionization modes generated mass spectra with sufficient analyte signals, detecting a broad range of molecules from polar compounds like caffeine and PEG 600, to nonpolar analytes, such as anthracene and wax esters, all within a single analytical run. Detection limits were found in the tens of attomoles per ablated/desorbed pixel. The powerful capabilities of the fully automated rDUVLAESCI dual source were demonstrated by visualizing the spatial distribution of new psychoactive substances on latent fingerprints. MSI for both sebum components and psychoactive substances revealed a connection between the chemical evidence and biometrical information. The rDUVLAESCI-MSI enabled the unambiguous identification of individuals, even using partially overlapped latent fingerprints. This unique rDUVLAESCI approach, with its remote laser ablation unit, improved spatial resolution and analyte coverage, particularly for nonpolar compounds.

Analytical ChemistryVol. 97(4)
Palacký University Olomouc (CZ)
Univerzita Palackého v Olomouci
Openalex Percentile: Top 22%
Mass Spectrometry Techniques and Applications
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Remote Deep-Ultraviolet Laser Ablation in Connection with Electrospray Ionization–Atmospheric Pressure Chemical Ionization (rDUVLAESCI): A Novel Dual Ionization Source for Molecular Mass Spectrometry — Barbora Papoušková, Tomáš Pluháček, et al. · Analytical Chemistry (2025) | TGRS Research Map | TGRS