Safety and efficacy of a modified suprachoroidal silicone tube shunt implant in primary open angle and pseudo-exfoliative glaucoma

PurposeTo assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.MethodsIn this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.ResultsThe average follow-up period was 18.56 ± 7.93 months. Mean baseline IOP reduced from 27.02 ± 5.43 mmHg to 13.23 ± 3.70 mmHg (<i>p</i> < 0.001). Mean number of ocular hypotensive medications reduced from 3.17 ± 0.89 to 1.83 ± 1.44 (<i>p</i> < 0.001). BCVA remained stable in 49 eyes (74.2%) throughout the follow-up period. Mean baseline BCVA of 0.73 ± 0.27 slightly declined to 0.68 ± 0.30 at the final follow-up (<i>p</i> < 0.001). Three adverse events of special interest (AESI) were observed hypotonic maculopathy, anterior chamber inflammation with pupillary membranes, and macular edema. None of these events was related to the SST shunt. Other complications such as intra and early postoperative hyphema in 3 and tube-iris contact causing slight corectopia in 2 cases were noted.ConclusionsThe surgical technique and device studied in this work demonstrated a good safety profile and signal of efficacy. This device may serve as a bridge between minimally invasive glaucoma surgeries (MIGS) and conventional filtering or episcleral tube shunt surgeries. A larger scale prospective trial is planned.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2025-01-22
DOI
https://doi.org/10.1177/11206721251314532
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety and efficacy of a modified suprachoroidal silicone tube shunt implant in primary open angle and pseudo-exfoliative glaucoma

Nikoloz Labauri, Tekla Mamageishvili, Yoram Solberg, Mikheil Omiadze et al.
European Journal of Ophthalmology
Glaucoma and retinal disorders
article

Safety and efficacy of a modified suprachoroidal silicone tube shunt implant in primary open angle and pseudo-exfoliative glaucoma

Nikoloz Labauri, Tekla Mamageishvili, Yoram Solberg, Mikheil Omiadze, Ana Vachiberidze, Lika Svanadze, Monika P. Zalinian, Marine Shakarashvili, Luka Sabanadze, Orkhan Huseynov, Tamar Sulkhanishvili, Maka Labauri
article en

Abstract

PurposeTo assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.MethodsIn this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.ResultsThe average follow-up period was 18.56 ± 7.93 months. Mean baseline IOP reduced from 27.02 ± 5.43 mmHg to 13.23 ± 3.70 mmHg (<i>p</i> < 0.001). Mean number of ocular hypotensive medications reduced from 3.17 ± 0.89 to 1.83 ± 1.44 (<i>p</i> < 0.001). BCVA remained stable in 49 eyes (74.2%) throughout the follow-up period. Mean baseline BCVA of 0.73 ± 0.27 slightly declined to 0.68 ± 0.30 at the final follow-up (<i>p</i> < 0.001). Three adverse events of special interest (AESI) were observed hypotonic maculopathy, anterior chamber inflammation with pupillary membranes, and macular edema. None of these events was related to the SST shunt. Other complications such as intra and early postoperative hyphema in 3 and tube-iris contact causing slight corectopia in 2 cases were noted.ConclusionsThe surgical technique and device studied in this work demonstrated a good safety profile and signal of efficacy. This device may serve as a bridge between minimally invasive glaucoma surgeries (MIGS) and conventional filtering or episcleral tube shunt surgeries. A larger scale prospective trial is planned.

European Journal of OphthalmologyVol. 35(4)
Tbilisi State University (GE)
Good health and well-being
Openalex Percentile: Top 97%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.