Evaluation and comparison of reading man flap based on different designs of angles and central axial lengths using finite element method

Different angles and central axis length combinations of the reading man flap were studied to determine the optimal angles and central axis length combinations for reducing the stress on the flap tip. First, different models and corresponding finite element models of flaps with different angles and central axial lengths were established by ANSYS software. Then, skin flap transfer was achieved through forced displacement, and the stress distributions of the flap with different angles and central axial lengths under different materials were obtained. Finally, the stress distributions of the flaps of each case were compared and analysed. The results shows: (1) The optimal angle and central axis for reducing the stress of the flap tip are 60° for the quadrangular flap, 45° for the triangular flap, with a 2 fold increase in length of the central axial relative to the diameter of the circular defects. (2) The quadrangular flap tip tends to have a greater possibility of complications than does the triangular flap tip. (3) The stress of the triangular flap tip is more sensitive to the angle and central axis length. (4) The stress of the flap tip in elderly people is greater than that in young people with the same design and position, which leads to greater possibility of complications at the flap tip in elderly patients than in young patients.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-01-22
DOI
https://doi.org/10.1038/s41598-025-87141-1
Citations
2
Primary Topic
Hand Gesture Recognition Systems
Type
article
Field-Weighted Citation Impact
3.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and comparison of reading man flap based on different designs of angles and central axial lengths using finite element method

Xinqi Yang, Long Zhang, Ling Chen, Youchen Xia et al.
2 citations
Scientific Reports
Hand Gesture Recognition Systems
3.87
article

Evaluation and comparison of reading man flap based on different designs of angles and central axial lengths using finite element method

Xinqi Yang, Long Zhang, Ling Chen, Youchen Xia, Yunshi Zhang
article en
2 citations

Abstract

Different angles and central axis length combinations of the reading man flap were studied to determine the optimal angles and central axis length combinations for reducing the stress on the flap tip. First, different models and corresponding finite element models of flaps with different angles and central axial lengths were established by ANSYS software. Then, skin flap transfer was achieved through forced displacement, and the stress distributions of the flap with different angles and central axial lengths under different materials were obtained. Finally, the stress distributions of the flaps of each case were compared and analysed. The results shows: (1) The optimal angle and central axis for reducing the stress of the flap tip are 60° for the quadrangular flap, 45° for the triangular flap, with a 2 fold increase in length of the central axial relative to the diameter of the circular defects. (2) The quadrangular flap tip tends to have a greater possibility of complications than does the triangular flap tip. (3) The stress of the triangular flap tip is more sensitive to the angle and central axis length. (4) The stress of the flap tip in elderly people is greater than that in young people with the same design and position, which leads to greater possibility of complications at the flap tip in elderly patients than in young patients.

Scientific ReportsVol. 15(1)
Peking University (CN), Peking University Third Hospital (CN)
Peking University, Peking University Third Hospital
Quality Education
Openalex Percentile: Top 9%
Hand Gesture Recognition Systems
3.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation and comparison of reading man flap based on different designs of angles and central axial lengths using finite element method — Xinqi Yang, Long Zhang, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS