YAG-laser treatment of secondary cataract with silicone tamponade of the vitreous cavity

BACKGROUND: Silicone tamponade of the vitreous cavity can be indefinitely long due to severe forms of diabetic retinopathy, recurrent hemophthalmos, and recurrent retinal detachment. Prolonged contact of the capsular bag with tamponade agent leads to posterior capsule fibrosis and cataract development, including secondary cataract in pseudophakia, which significantly reduces the visual outcome of surgery. The technique of laser posterior capsulotomy has some peculiarities related to the tight contact of the posterior capsule with the silicone oil. Often the procedure cannot be completed successfully, and surgical dissection of the secondary cataract has to be performed. Repeated surgical procedure also has certain complexities and becomes even more risky, as there is an increased risk of IOL damage, IOL dislocation, and migration of silicone oil into the anterior chamber, which does not allow to improve the functional outcome of the intervention. AIM: The aim of this study is to develop and present the own modified technique of YAG-laser posterior capsulotomy in eyes after vitrectomy with long-term silicone oil tamponade. MATERIALS AND METHODS: This study presents the results of treatment of 12 patients (12 eyes), including 2 women and 10 men (16.67% and 83.33%), age from 16 to 60 (42.83 ± 7.89) years with prolonged “light” silicone oil tamponade and secondary cataract. Posterior capsulotomy was performed with YAG-laser using the developed technology. Best-corrected visual acuity before surgery ranged from 0.01 to 0.2 (0.07 ± 0.01), intraocular pressure before surgery ranged from 7 to 20 (11.83 ± 2.21) mm Hg. The term of silicone tamponade was from 4 to 51 (24 ± 6.48) months. The follow-up time for patients operated using this technology ranged from 1 to 60 (27.33 ± 9.95) days. RESULTS: As a result of treatment, the dissection of the posterior lens capsule was achieved in 12 out of 12 patients (100%). No intraoperative and postoperative complications were observed. Postoperative best-corrected visual acuity ranged from 0.05 to 0.3 (0.13 ± 0.02), and intraocular pressure from 7 to 22 (13 ± 2.37) mm Hg. In all cases, the diameter of the optical area was sufficient and amounted to 3–4 mm, the flap of the posterior capsule was completely separated as a whole fragment. CONCLUSIONS: The developed method of modified YAG-laser posterior capsulotomy (Patent RU No. 2782725, priority from December 27, 2021) in eyes with a long term silicone oil tamponade is effective and can be used in everyday medical practice. The advantages of the proposed method: high efficacy when performing the procedure in a complex category of patients with no additional procedures required. The procedure is a modification of a routine technology, and does not require additional equipment and training.

Authors

Institutions

Publication Details

Journal
Ophthalmology Reports
Published
2024-09-30
DOI
https://doi.org/10.17816/ov516561
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

YAG-laser treatment of secondary cataract with silicone tamponade of the vitreous cavity

N.V. Strenev, Oleg A. Zykov, Andrei Yu. Kleimenov, P.S. Ratanova et al.
Ophthalmology Reports
Retinal and Macular Surgery
article

YAG-laser treatment of secondary cataract with silicone tamponade of the vitreous cavity

N.V. Strenev, Oleg A. Zykov, Andrei Yu. Kleimenov, P.S. Ratanova, Nataliya S. Shuman, Anastasiya D. Arapova
article en

Abstract

BACKGROUND: Silicone tamponade of the vitreous cavity can be indefinitely long due to severe forms of diabetic retinopathy, recurrent hemophthalmos, and recurrent retinal detachment. Prolonged contact of the capsular bag with tamponade agent leads to posterior capsule fibrosis and cataract development, including secondary cataract in pseudophakia, which significantly reduces the visual outcome of surgery. The technique of laser posterior capsulotomy has some peculiarities related to the tight contact of the posterior capsule with the silicone oil. Often the procedure cannot be completed successfully, and surgical dissection of the secondary cataract has to be performed. Repeated surgical procedure also has certain complexities and becomes even more risky, as there is an increased risk of IOL damage, IOL dislocation, and migration of silicone oil into the anterior chamber, which does not allow to improve the functional outcome of the intervention. AIM: The aim of this study is to develop and present the own modified technique of YAG-laser posterior capsulotomy in eyes after vitrectomy with long-term silicone oil tamponade. MATERIALS AND METHODS: This study presents the results of treatment of 12 patients (12 eyes), including 2 women and 10 men (16.67% and 83.33%), age from 16 to 60 (42.83 ± 7.89) years with prolonged “light” silicone oil tamponade and secondary cataract. Posterior capsulotomy was performed with YAG-laser using the developed technology. Best-corrected visual acuity before surgery ranged from 0.01 to 0.2 (0.07 ± 0.01), intraocular pressure before surgery ranged from 7 to 20 (11.83 ± 2.21) mm Hg. The term of silicone tamponade was from 4 to 51 (24 ± 6.48) months. The follow-up time for patients operated using this technology ranged from 1 to 60 (27.33 ± 9.95) days. RESULTS: As a result of treatment, the dissection of the posterior lens capsule was achieved in 12 out of 12 patients (100%). No intraoperative and postoperative complications were observed. Postoperative best-corrected visual acuity ranged from 0.05 to 0.3 (0.13 ± 0.02), and intraocular pressure from 7 to 22 (13 ± 2.37) mm Hg. In all cases, the diameter of the optical area was sufficient and amounted to 3–4 mm, the flap of the posterior capsule was completely separated as a whole fragment. CONCLUSIONS: The developed method of modified YAG-laser posterior capsulotomy (Patent RU No. 2782725, priority from December 27, 2021) in eyes with a long term silicone oil tamponade is effective and can be used in everyday medical practice. The advantages of the proposed method: high efficacy when performing the procedure in a complex category of patients with no additional procedures required. The procedure is a modification of a routine technology, and does not require additional equipment and training.

Ophthalmology ReportsVol. 17(4)
Intersectoral Research and Technology Complex Eye Microsurgery (RU), Dagestan Center of Eye Microsurgery (RU)
Openalex Percentile: Top 57%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.