Simulation of the energy model of a rural house located in a cold climate using an in-situ monitoring system

The energy simulation of buildings is presented as a tool to analyze the comfort, consumption and energy efficiency of buildings, however, the discrepancy between simulated models and real data has been a constant, for this reason, energy model calibrations are performed to increase the reliability of the predictions of the simulation. This research carried out the simulation and calibration of the energy model of a rural house, located in a cold climate at more than 3000 meters above sea level, the study was developed in three phases, starting with the monitoring of climatological variables, followed by the energy modeling and finally, the calibration of the model is achieved by applying the iterative and scatter plot methods, allowing the selection of a model where a sequence of linear data was observed, with a strong relationship of more than 80% accuracy between the monitored data and the simulated energy model.

Authors

Publication Details

Journal
Periodicals of Engineering and Natural Sciences (PEN)
Published
2024-12-25
DOI
https://doi.org/10.21533/pen.v12.i3.59
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of the energy model of a rural house located in a cold climate using an in-situ monitoring system

N. Y. Castillo-Leon, J G Ascanio-Villabona, K T Jaimes-Quintero, B E Tarazona-Romero et al.
Periodicals of Engineering and Natural Sciences (PEN)
Building Energy and Comfort Optimization
article

Simulation of the energy model of a rural house located in a cold climate using an in-situ monitoring system

N. Y. Castillo-Leon, J G Ascanio-Villabona, K T Jaimes-Quintero, B E Tarazona-Romero, Nicolas Orejarena Osorio
article en

Abstract

The energy simulation of buildings is presented as a tool to analyze the comfort, consumption and energy efficiency of buildings, however, the discrepancy between simulated models and real data has been a constant, for this reason, energy model calibrations are performed to increase the reliability of the predictions of the simulation. This research carried out the simulation and calibration of the energy model of a rural house, located in a cold climate at more than 3000 meters above sea level, the study was developed in three phases, starting with the monitoring of climatological variables, followed by the energy modeling and finally, the calibration of the model is achieved by applying the iterative and scatter plot methods, allowing the selection of a model where a sequence of linear data was observed, with a strong relationship of more than 80% accuracy between the monitored data and the simulated energy model.

Periodicals of Engineering and Natural Sciences (PEN)Vol. 12(3)
Openalex Percentile: Top 72%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of the energy model of a rural house located in a cold climate using an in-situ monitoring system — N. Y. Castillo-Leon, J G Ascanio-Villabona, et al. · Periodicals of Engineering and Natural Sciences (PEN) (2024) | TGRS Research Map | TGRS