Effect of Transformer Rating on the Power Quality Problems in 11kv/440v Distribution System

This study explains in detail how the transformer rating affects the proposed distribution system. Also analysis of the suggested distribution system would react when the transformer rating is changed to reduce harmonic interference, this information is essential. The harmonic in the voltage waveform is changed by changing the transformer's rating. The nonlinear and imbalanced load is taken into account in this approach. To reduce harmonics caused by nonlinear and imbalanced loads along with by adjusting the transformer's rating up or down, an SRF-controlled algorithm is suggested. An 11kV/400V distribution system framework, the SRF- controlled DSTATCOM with four-leg VSI is proposed and placed into the system. The proposed DSTATCOM is evaluated for its ability to regulate the voltage at the PCC as the transformer rating rises and falls in nonlinear and imbalanced load conditions. The outcomes of the suggested work are acquired using the MATLAB/SIMULINK program.

Authors

Publication Details

Journal
WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS
Published
2024-12-31
DOI
https://doi.org/10.37394/23201.2024.23.27
Citations
1
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Transformer Rating on the Power Quality Problems in 11kv/440v Distribution System

S. Rama Reddy, P. Parthasaradhy, Amar Bharatrao Deshmukh, K. Atnakishori
1 citations
WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS
Power Quality and Harmonics
0.21
article

Effect of Transformer Rating on the Power Quality Problems in 11kv/440v Distribution System

S. Rama Reddy, P. Parthasaradhy, Amar Bharatrao Deshmukh, K. Atnakishori
article en
1 citations

Abstract

This study explains in detail how the transformer rating affects the proposed distribution system. Also analysis of the suggested distribution system would react when the transformer rating is changed to reduce harmonic interference, this information is essential. The harmonic in the voltage waveform is changed by changing the transformer's rating. The nonlinear and imbalanced load is taken into account in this approach. To reduce harmonics caused by nonlinear and imbalanced loads along with by adjusting the transformer's rating up or down, an SRF-controlled algorithm is suggested. An 11kV/400V distribution system framework, the SRF- controlled DSTATCOM with four-leg VSI is proposed and placed into the system. The proposed DSTATCOM is evaluated for its ability to regulate the voltage at the PCC as the transformer rating rises and falls in nonlinear and imbalanced load conditions. The outcomes of the suggested work are acquired using the MATLAB/SIMULINK program.

WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMSVol. 23
Openalex Percentile: Top 44%
Power Quality and Harmonics
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.