Using equivalent keratometric readings in calculating the optical power of a multifocal intraocular lens

BACKGROUND: Modern keratotopography allows calculating Equivalent Keratometer Readings (EKR), which take additionally into account in keratometry the radius of curvature of corneal posterior surface, and this could lead to more accurate calculation of the spherical equivalent (SE) of the intraocular lens. AIM: The aim of this study is to determine the accuracy of calculating the SE of multifocal intraocular lens according to EKR data, depending on the formula used and the corneal zone. MATERIALS AND METHOD: The study included 78 patients who underwent femtolaser-assisted phacoemulsification, multifocal intraocular lens implantation and achievement of the target refraction at different distances. Retrospective calculation of the optical power of the intraocular lens was performed using biometric data from OA-2000 and EKR (zones from 0.5 to 5 mm in increments of 0.5 mm) using 10 formulas (SRK/T, Holladay 1, Holladay 2, Haigis, Hoffer Q, Barrett 2 Universal, Olsen, Kane, EVO, Hill RBF). For each combination of keratometry zone/formula were calculated: mean error of predicted refraction (ME), its difference from zero, and after intraocular lens constant optimization — mean (MAE) and median (MedAE) absolute errors, standard deviation (SD). RESULTS: Up to the 2.5 mm zone, ME is shifted towards hypermetropia, and from the 3 mm zone, ME begins to shift towards myopia according to all formulas. Minimal MAE, MedAE and SD values were detected in peripheral corneal zones (3–5 mm) for most formulas. The best indicators were demonstrated by the formula Haigis in zones 3.5–5 mm. CONCLUSIONS: The most accurate calculation of the SE of a multifocal intraocular lens using EKR is possible when using the Haigis formula in 3.5–5 mm zones.

Authors

Institutions

Publication Details

Journal
Ophthalmology Reports
Published
2024-12-30
DOI
https://doi.org/10.17816/ov626398
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using equivalent keratometric readings in calculating the optical power of a multifocal intraocular lens

S. V. Shukhaev, Y.M. Petrosyan, Ernest V. Boiko, Anton V. Molodkin
Ophthalmology Reports
Corneal surgery and disorders
article

Using equivalent keratometric readings in calculating the optical power of a multifocal intraocular lens

S. V. Shukhaev, Y.M. Petrosyan, Ernest V. Boiko, Anton V. Molodkin
article en

Abstract

BACKGROUND: Modern keratotopography allows calculating Equivalent Keratometer Readings (EKR), which take additionally into account in keratometry the radius of curvature of corneal posterior surface, and this could lead to more accurate calculation of the spherical equivalent (SE) of the intraocular lens. AIM: The aim of this study is to determine the accuracy of calculating the SE of multifocal intraocular lens according to EKR data, depending on the formula used and the corneal zone. MATERIALS AND METHOD: The study included 78 patients who underwent femtolaser-assisted phacoemulsification, multifocal intraocular lens implantation and achievement of the target refraction at different distances. Retrospective calculation of the optical power of the intraocular lens was performed using biometric data from OA-2000 and EKR (zones from 0.5 to 5 mm in increments of 0.5 mm) using 10 formulas (SRK/T, Holladay 1, Holladay 2, Haigis, Hoffer Q, Barrett 2 Universal, Olsen, Kane, EVO, Hill RBF). For each combination of keratometry zone/formula were calculated: mean error of predicted refraction (ME), its difference from zero, and after intraocular lens constant optimization — mean (MAE) and median (MedAE) absolute errors, standard deviation (SD). RESULTS: Up to the 2.5 mm zone, ME is shifted towards hypermetropia, and from the 3 mm zone, ME begins to shift towards myopia according to all formulas. Minimal MAE, MedAE and SD values were detected in peripheral corneal zones (3–5 mm) for most formulas. The best indicators were demonstrated by the formula Haigis in zones 3.5–5 mm. CONCLUSIONS: The most accurate calculation of the SE of a multifocal intraocular lens using EKR is possible when using the Haigis formula in 3.5–5 mm zones.

Ophthalmology ReportsVol. 17(4)
St Petersburg University (RU), Intersectoral Research and Technology Complex Eye Microsurgery (RU), North-Western State Medical University named after I.I. Mechnikov (RU)
Openalex Percentile: Top 57%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.